The following table documents the compatibility commands that the Agilent N5700 power supplies support. All compatibility commands are accepted; however, some commands do nothing.

Compatibility Command

Description

Similar SCPI

 

 

Command

ASTS?

Queries the accumulated status (ASTS). The response represents the sum

 

of the binary weights of the ASTS register bits. The ASTS register is set to

 

the present status after being queried.

CLR

Returns the power supply to the power-on state. Same as *RST.

DLY <delay>

Generates error 203.

DLY?

Generates error 203.

ERR?

Queries the present programming or hardware error. An error code number

 

is returned over the GPIB to identify the error. The error register is cleared

 

after being read.

FAULT?

Queries the fault register. A bit is set in the fault register when the

 

corresponding bit in both the status and the mask registers. The response

 

is an integer 0 to 255. The fault register is cleared after being read.

FOLD

Turns the OCP on or off. This is only allowed for constant current mode

 

(FOLD 2). Constant voltage mode (FOLD1) generates error 203.

FOLD?

Queries the OCP setting. The response is FOLD 2.

HOLD

When turned on (HOLD 1), causes the VSET, ISET, FOLD, and UNMASK

 

values to be held until a trigger occurs. This only applies to the

 

compatibility functions, not the SCPI functions

HOLD?

Queries the hold setting. The response is HOLD 1.

ID?

Queries the identification (model number) of the power supply.

IMAX

Sets a soft programming limit for current. Attempting to program the

 

current above this setting will generate an error.

IMAX?

Queries the IMAX setting. The response is a real number.

IOUT?

Queries the measured output current. The response is a real number.

ISET <current>

Sets the output current.

ISET?

Queries the present current setting. The response is a real number.

OUT <onoff>

Turns the output on or off. On/off equals 1 turns the output on; equals 0

 

turns the output off.

OUT?

Queries whether the output is turned on or off . The response is OUT 1 (on)

 

or OUT O (off). The front panel displays OFF when the output is off.

STAT:OPER:EVEN?

STAT:QUES:EVEN?

*ESE?

*RST

SYST:ERR?

STAT:OPER?

STAT:QUES?

*ESE?

CURR:PROT:STAT

CURR:PROT:STAT?

VOLT:TRIG

CURR:TRIG

*IDN?

MEAS:CURR?

CURR

CURR?

OUTP:STAT

OUTP:STAT?

Series N5700 User’s Guide

123

Page 123
Image 123
Agilent Technologies N5700 manual Compatibility Command Summary, Description Similar Scpi Command

N5700 specifications

Agilent Technologies, now part of Keysight Technologies, is renowned for its innovative solutions in electronic measurement and instrumentation. Among its impressive portfolio, the Agilent N5700 series of power supplies stands out, providing precision, reliability, and versatility for a range of applications in test and measurement.

The N5700 series features multiple models, each designed to meet the varying power requirements of test systems and electronic devices. One of its key characteristics is its adjustable output voltage and current, allowing users to set parameters according to specific test needs. With outputs ranging from 0 to 60 V and up to 6 A, the N5700 series caters to both low and high-power applications effectively.

A notable technology integrated into the N5700 series is its advanced measurement capabilities. The built-in voltmeter and ammeter enable real-time monitoring of output voltage and current, ensuring precise control over the power supplied to the device under test. This feature is particularly advantageous in troubleshooting and optimization scenarios, providing engineers with immediate feedback on performance.

The N5700 also embraces the latest in power supply control technology with its intuitive user interface. The front panel incorporates a clear display and simple navigation controls, allowing users to program settings easily and access functions without extensive training. Additionally, remote programming capabilities via GPIB, USB, or LAN facilitate integration into automated test setups, enhancing productivity and efficiency.

Thermal management is another hallmark of the N5700 series. Its design ensures effective heat dissipation, enabling reliable operation even under demanding conditions. This robustness is critical in environments where consistent performance is essential, such as in research laboratories and manufacturing facilities.

Furthermore, safety features are thoughtfully included in the N5700 series, such as overvoltage protection, overcurrent protection, and short-circuit protection. These elements assure users that their devices and test setups remain secure during testing, minimizing the risk of damage.

In summary, the Agilent N5700 series power supplies encapsulate the fusion of precision, advanced measurement technology, user-friendly design, thermal management, and robust safety features. This combination makes them an invaluable tool for engineers and researchers engaged in electronic testing and development across various industries. With its versatility and reliability, the N5700 series continues to play a pivotal role in advancing electronic measurement methodologies.