4-6 N9360A Multi UE Tester Quick Reference Guide
4GSM System
Figure 4-5 Various [Manual Test (GSM): Stand-by] Screens
7While “Connection” is highlighted in the test flow, press the
Trig ger softkey to start single measurement or the Trig g e r
Sing/Cont softkey to start continuous measurement. Press the
Trig ge r Si ng /Cont softkey again to terminate the continuous
measurement.
8Place the cursor at one of the groups of the test items and
press the knob or press the Spectrum Monitor softkey to display
a measurement result screen according to your selection.
Then, press the Trig ger softkey to start single measurement or
Trig g er Sing/Cont softkey to start continuous measurement.
Spectrum
Monitor
Sensitivity
RX Quality
RX Level
Phase Error
Frequency Error
Peak TX Power/ Burst
Timing/ Power Ramp