2 | INSTALLATION |
|
|
| |||
|
|
|
|
|
|
|
|
| Mounting locations |
|
|
| |||
| 1 Install | the master monitor station in a place | 2 The master monitor station has switches on | 3 Allow at least 15 cm (6") of vertical open | |||
| where the screen is not exposed to direct | both sides. Allow at least 5 cm (2") of open | space from the center of the mounting | ||||
| sunlight. | space on either side. | bracket in order to mount the master | ||||
|
|
|
|
|
| monitor station. |
English
2
+5 cm (2")
+ 5 cm
(2")
3
+15 cm (6")
Français
2-2 Wiring method, wiring distance
Wire the units from station-to-station (daisy-chained).
| A |
| |
| |||
| |||
|
| ||
| |||
| |||
2 | 4 | ||
|
| B | C |
| Ø 0,65 mm | 22 AWG | Ø 1,0 mm | 18 AWG |
|
|
| |||||
|
| A | 50 m | 165' | 100 m | 330' | |
|
|
| |||||
PS18 |
| B | 5 m | 16' | 10 m | 33' | |
|
| C | 75 m | 245' | 150 m | 490' | |
|
|
|
|
|
|
|
|
|
|
1 Use PVC jacket with PE (polyethylene) insulated cable | 3 When using a cable with unused conductors, terminate both ends of | |
| the unused pair(s) with a 120 Ω resistor. | |
| ||
(x2) | A1 | B1 |
| A2 | B2 |
| S | SW |
2 Never use individual conductors, twisted pair cable or coaxial cable. | S | SW |
B1 | + | |
| B2 | - |
| L |
|
| L |
|
| + |
|
| - |
|
| 120 | 120 |
Nederlands
- 3 -