- 9 -
English Français Nederlands
7-5 EXTERNAL INPUT SETTING
When optional units operate (for example, when a sensor is activated or
call button is pressed), the master monitor station and sub master station
will receive an alert sound. Also, when notification at door is enabled,
the door station also receives an alert sound.
These operations must be performed by an installer. Please do not
change these settings yourself.
7-6 Setting communication time
Select the door station communication time from "1 min.", "2 min.", "3
min.", and "5 min.". Communication time initial setting: "1 min."
1 After performing step 1 in section 7-1, select "COMMUNICATION"
and press MENU button ( ).
2
In the "COMMUNICATION SETTING" screen, press button or
button to select "COMM. TIME" and press MENU button ( )
.
3 In the "COMMUNICATION TIME-OUT SETTING" screen, press
button or button to select the communication time.
4 Press MENU button ( ) to complete the settings and return
to the previous screen. Press REC button ( ) to cancel the
setting and return to the previous screen.
7-5-1 Setting the optional units detection method.
Initial setting
1 After performing steps 1 and 2 in section 7-1, select "EXT. INPUT"
and press MENU button ( ).
2 In the "EXTERNAL INPUT SETTING" screen, press button and
button to select "DETECTION METHOD" and press MENU
button ( ).
3 In the "EXTERNAL INPUT DETECTION METHOD" screen, press
button or button to select the detection method.
: dry closure contact input
: dry closure contact input
: External input disabled
4 Press MENU button ( ) to complete the settings and return to
the previous screen.
7-5-2 Setting the alert sound time.
Initial setting: Notification at door disabled/alert sound
is 30 sec.
1 In the "EXTERNAL INPUT SETTING" screen, press button or
button to select "NOTICE AT DOOR [1]" and press MENU
button ( ).
2 In the "NOTIFICATION AT DOOR SETTING" screen, press
button or button to select the "Notification method".
DISABLE 30SEC
: Notification at door
disabled/alert sound is 30
sec.
DISABLE CONT.
: Notification at door
disabled/alert sound is
continuous
ENABLE CONT.
: Notification at door
enabled/alert sound is
continuous
3 Press MENU button ( ) to complete the settings and return
to the previous screen. Press REC button ( ) to cancel the
setting and return to the previous screen.