AIRSTREAM LAND YACHT GAS
STEP 3
Action: Press and release the status switch 1 time.
Display will light Fresh Water, Gray Water 1, Gray Water 2,
Black Water, and Select Tank LED’s green. After 2 seconds,
the Select Tank LED will turn off and the ready for empty LED
will turn light green. Proceed to step 4.
On all diagrams the Letters R=Red, Y=Yellow, Blank=no LED
lit.
Display after completion of step 3.
On all diagrams the Letters R=Red, G=Green, Y=Yellow,
Blank=no LED lit.
STEP 4
Action: Fill all water holding tanks to the level that you want
the monitor to report empty. Minimum suggested is liquid just
covering the sensor. When all tanks are set to the desired level
press and release the status button 1 time.
Result: Display will go blank for a few moments while the empty
values are being read. When the system has completed reading the
empty values Fresh Water, Gray Water 1, Gray Water 2, Black
Water, and the Ready For Full LED’s will light green. Proceed t
step 5. o
Display after completion of step 4.
On all diagrams the Letters R=Red, G=Green, Y=Yellow,
Blank=no LED lit.
H-12