AIRSTREAM LAND YACHT GAS

LP TANK INSTALLATION
The regulator at the L.P. tank is
under a black plastic cover. The
protective cover certainly helps
to keep the vent on the regulator
from getting clogged by wasps
or ice, but should still be
checked regularly to make sure
the vent remains clear.
WARNING: Do not attempt to seal regulator cover.
WARNING: Check vent each time tank is filled to make sure it is clear of
obstructions.
Gas Regulator Removal/Replacement
1. Shut off main gas supply at the tank.
2. Remove the plastic protective cover from the regulator assembly
3. Using two wrenches, one to hold the line fitting and one to turn the flare nut, disconnect
the regulator from the flexible rubber line.
4. Disconnect the regulator from the tank fitting. Remove regulator.
5. To replace, reverse the removal procedures.

G-3