7. PROBLEMS DURING OPERATION AND START-UP
ProblemCheckCycle does not start | - doors not closed correctly |
| - emergency stop activated |
| - contact breaker or |
| electricity outage |
Control panel does not | - fuses tripped |
light up | - emergency stop activated |
| - processor off |
| - electricity outage |
Cycle starts but drum | - fuse of regulator tripped |
does not turn | - press yellow indicator light |
| on front side when it is on |
Cycle starts but water | - water inlet closed |
does not enter | - pressure switch out of |
| service |
| - electronic valve out of |
| service |
| - fuse tripped |
| - electronic valve of inlet out |
| of service |
Cycle starts but water | - pressure switch out of |
inflow does not stop | service |
| - electronic valve dirty |
| - tub pressure switch |
| clogged |
| - drainage valve still open |
Cycle starts but heating | - required water level not |
does not engage | reached |
| - fuse tripped |
| - contact coil heating out of |
| service |
| - HS probe |
Heating is on but | - resistor out of service |
temperature does not rise |
|
|