Programming

7.The even-numbered side of the program timer can be configured with jumpers to adjust the rinse temperature or to change the water level for the wash step. Either or both even-side jumper configurations may be used in conjunction with any of the 11 permissible odd-side jumper combinations. See Figure 13.

20b 20 20a

18b 18 18a

16b 16 16a

14b 14 14a

12b 12 12a

10b 10 10a

8b 8 8a

6b 6 6a

4b 4 4a

2b 2 2a

0b 0 0a

Figure 16

Figure 17 and Figure 18 illustrate the different options available.

2a to 2b

This jumper configuration changes the fill temperature for the rinses from cold to warm for all cycles. See Figure 17.

4b 4 4a

2b 2 2a

0b 0 0a

Figure 17

10a to 10b

This jumper configuration changes the water level for the wash segment from low to high for all cycles. See Figure 18.

12b 12 12a

10b 10 10a

8b 8 8a

Figure 18

NOTE: This jumper configuration will cause the timer to advance once low water level is reached. The fill valves will remain open until high water level is reached.

8.Replace the timer bracket screws if they were removed in step 5.

9.Replace the control module cover and mounting screws.

10.Reconnect power to the machine.

22

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232088