Installation/Operation Supplement

 

 

Table 1 (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

18 Pound

 

25 Pound

 

 

 

 

 

 

 

 

Power Consumption

 

 

 

 

 

 

 

 

Average power used per cycle, kWh

 

 

 

0.2

 

0.3

 

 

 

 

 

 

 

Nominal sound emission, dBA

 

 

 

58

 

Data not available

 

 

 

 

 

 

 

Average HVAC load, kcal/hr (Btu/hr)

 

 

 

101 (400)

 

113 (450)

 

 

 

 

 

 

 

 

Drive Train Information

 

 

 

 

 

 

 

 

Number of motors in drive train

 

 

 

1

 

1

 

 

 

 

 

 

 

Drive motor power, kW (HP)

 

 

 

0.75 (1.0)

 

1.50 (2.0)

 

 

 

 

 

 

 

 

Cylinder Speeds

 

 

 

 

 

 

 

 

Low wash/reverse speed, RPM

 

 

 

29

 

27

 

 

 

 

 

 

 

Normal wash/reverse speed, RPM

 

 

 

52

 

49

 

 

 

 

 

 

 

Distribution speed, RPM

 

 

 

86

 

73

 

 

 

 

 

 

 

Extract l, RPM

 

 

 

534

 

500

 

 

 

 

 

 

 

Extract 2, RPM

 

 

 

685

 

641

 

 

 

 

 

 

 

Extract 3, RPM

 

 

 

1080

 

1011

 

 

 

 

 

 

 

 

Centrifugal Force Data

 

 

 

 

 

 

 

 

Low wash/reverse centrifugal force, Gs

 

 

 

0.25

 

0.80

 

 

 

 

 

 

 

Normal wash/reverse centrifugal force, Gs

 

 

 

0.80

 

0.80

 

 

 

 

 

 

 

Distribution centrifugal force, Gs

 

 

 

2.20

 

1.80

 

 

 

 

 

 

 

Extract 1 centrifugal force, Gs

 

 

 

85

 

85

 

 

 

 

 

 

 

Extract 2 centrifugal force, Gs

 

 

 

140

 

140

 

 

 

 

 

 

 

Extract 3 centrifugal force, Gs

 

 

 

348

 

348

 

 

 

 

 

 

 

 

 

 

Load Balancing

 

 

 

 

 

 

 

 

 

Balance detection system

 

 

 

AC drive

 

AC drive

 

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

 

Steam inlet connection size, mm (in.)

 

 

 

DN15 (1/2 NPT)

 

DN15 (1/2 NPT)

 

 

 

 

 

 

 

Number of steam inlets

 

 

 

1

 

1

 

 

 

 

 

 

 

Steam required to

 

LOW

 

0.81 (1.13)

 

1.05 (1.46)

raise bath temperature

 

 

 

 

 

 

 

MED

 

0.90 (1.25)

 

1.16 (1.61)

10 ° C, kg (10 ° F, lb.)

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

1.04 (1.45)

 

1.33 (1.85)

 

 

 

 

 

 

 

Average steam use per cycle, kg (bhp)

 

 

 

11.7 (0.75)

 

15 (0.96)

 

 

 

 

 

 

 

F232148 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5