| Installation/Operation Supplement | |
|
| Table 1 (Continued) |
|
| ||
|
|
|
|
|
|
|
|
|
|
| 18 Pound |
| 25 Pound |
|
|
|
|
|
| |
|
| Power Consumption |
|
| ||
|
|
|
|
|
| |
Average power used per cycle, kWh |
|
|
| 0.2 |
| 0.3 |
|
|
|
|
|
|
|
Nominal sound emission, dBA |
|
|
| 58 |
| Data not available |
|
|
|
|
|
|
|
Average HVAC load, kcal/hr (Btu/hr) |
|
|
| 101 (400) |
| 113 (450) |
|
|
|
|
|
| |
|
| Drive Train Information |
|
| ||
|
|
|
|
|
| |
Number of motors in drive train |
|
|
| 1 |
| 1 |
|
|
|
|
|
|
|
Drive motor power, kW (HP) |
|
|
| 0.75 (1.0) |
| 1.50 (2.0) |
|
|
|
|
|
| |
|
| Cylinder Speeds |
|
| ||
|
|
|
|
|
| |
Low wash/reverse speed, RPM |
|
|
| 29 |
| 27 |
|
|
|
|
|
|
|
Normal wash/reverse speed, RPM |
|
|
| 52 |
| 49 |
|
|
|
|
|
|
|
Distribution speed, RPM |
|
|
| 86 |
| 73 |
|
|
|
|
|
|
|
Extract l, RPM |
|
|
| 534 |
| 500 |
|
|
|
|
|
|
|
Extract 2, RPM |
|
|
| 685 |
| 641 |
|
|
|
|
|
|
|
Extract 3, RPM |
|
|
| 1080 |
| 1011 |
|
|
|
|
|
| |
|
| Centrifugal Force Data |
|
| ||
|
|
|
|
|
| |
Low wash/reverse centrifugal force, Gs |
|
|
| 0.25 |
| 0.80 |
|
|
|
|
|
|
|
Normal wash/reverse centrifugal force, Gs |
|
|
| 0.80 |
| 0.80 |
|
|
|
|
|
|
|
Distribution centrifugal force, Gs |
|
|
| 2.20 |
| 1.80 |
|
|
|
|
|
|
|
Extract 1 centrifugal force, Gs |
|
|
| 85 |
| 85 |
|
|
|
|
|
|
|
Extract 2 centrifugal force, Gs |
|
|
| 140 |
| 140 |
|
|
|
|
|
|
|
Extract 3 centrifugal force, Gs |
|
|
| 348 |
| 348 |
|
|
|
|
|
|
|
|
|
| Load Balancing |
|
| |
|
|
|
|
|
|
|
Balance detection system |
|
|
| AC drive |
| AC drive |
|
|
|
|
| ||
| Direct Steam Heating (Optional) |
|
| |||
|
|
|
|
|
|
|
Steam inlet connection size, mm (in.) |
|
|
| DN15 (1/2 NPT) |
| DN15 (1/2 NPT) |
|
|
|
|
|
|
|
Number of steam inlets |
|
|
| 1 |
| 1 |
|
|
|
|
|
|
|
Steam required to |
| LOW |
| 0.81 (1.13) |
| 1.05 (1.46) |
raise bath temperature |
|
|
|
|
|
|
| MED |
| 0.90 (1.25) |
| 1.16 (1.61) | |
10 ° C, kg (10 ° F, lb.) |
|
|
| |||
|
|
|
|
|
| |
|
| HIGH |
| 1.04 (1.45) |
| 1.33 (1.85) |
|
|
|
|
|
|
|
Average steam use per cycle, kg (bhp) |
|
|
| 11.7 (0.75) |
| 15 (0.96) |
|
|
|
|
|
|
|
F232148 (EN) | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 5 |