Installation/Operation Supplement

Table 2 (Continued)

 

 

 

 

35 Pound

50 Pound

85 Pound

 

 

 

 

 

 

 

Cylinder Speeds

 

 

 

 

 

 

 

 

 

 

Gentle wash/reverse speed, RPM

 

 

 

26

26

26

 

 

 

 

 

 

 

Wash/reverse speed, RPM

 

 

 

43

40

41

 

 

 

 

 

 

 

Distribution/drain speed, RPM

 

 

 

77

73

65

 

 

 

 

 

 

 

Medium extract speed, RPM

 

 

 

325

305

280

 

 

 

 

 

 

 

High extract speed l, RPM

 

 

 

475

445

410

 

 

 

 

 

 

 

High extract speed 2, RPM

 

 

 

610

575

525

 

 

 

 

 

 

 

High extract speed 3, RPM

 

 

 

960

900

825

 

 

 

 

 

 

Centrifugal Force Data

 

 

 

 

 

 

 

 

 

Gentle wash/reverse centrifugal force, Gs

 

 

 

0.25

0.29

0.345

 

 

 

 

 

 

 

Wash/reverse centrifugal force, Gs

 

 

 

0.69

0.68

0.858

 

 

 

 

 

 

 

Distribution/drain centrifugal force, Gs

 

 

 

2.2

2.3

2.16

 

 

 

 

 

 

 

Medium extract centrifugal force, Gs

 

 

 

40

40

40

 

 

 

 

 

 

 

High extract 1 centrifugal force, Gs

 

 

 

85

84

85.8

 

 

 

 

 

 

 

High extract 2 centrifugal force, Gs

 

 

 

140

141

141

 

 

 

 

 

 

 

High extract 3 centrifugal force, Gs

 

 

 

345

345

348

 

 

 

 

 

 

 

Balance Detection

 

 

 

 

 

 

 

 

 

 

Vibration safety switch installed

 

 

 

Standard

Standard

Standard

 

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

Steam inlet connection size, mm (in.)

 

DN15

 

DN15 (0.5)

DN15 (0.5)

DN15 (0.5)

 

 

 

 

 

 

 

Number of steam inlets

 

 

 

1

1

1

 

 

 

 

 

 

 

Steam required to raise bath temperature

 

LOW

 

2.22 (1.6)

2.91 (2.42)

3.8 (5.2)

10° C, kg (10° F, lb.)

 

 

 

 

 

 

 

MED

 

2.52 (1.81)

2.42 (3.46)

4.3 (5.9)

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

2.84 (2.04)

2.73 (3.80)

4.9 (6.9)

 

 

 

 

 

 

 

Average steam use per cycle, kg (bhp)

 

 

 

1.47 (23)

1.95 (30.6)

54.9 (3.5)

 

 

 

 

 

 

Electric Heating (Optional)

 

 

 

 

 

 

 

 

 

Total electric heating capacity, kW

 

 

 

15.6

23.4

31.2

 

 

 

 

 

 

 

Number of electrical heat elements

 

 

 

6

9

12

 

 

 

 

 

 

 

Electrical heat element size, kW

 

 

 

2.6

2.6

2.6

 

 

 

 

 

 

 

Time required to raise bath temperature

 

LOW

 

3.9 (2.6)

3.6 (2.4)

3.1 (4.8)

10°C, min. (10°F, min.)

 

 

 

 

 

 

 

MED

 

4.5 (2.9)

4.2 (2.7)

3.5 (5.4)

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

5.0 (3.3)

4.7 (3.1)

6.4 (4.1)

 

 

 

 

 

 

 

F232148 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

7