Installation/Operation Supplement
Table 2 (Continued)
|
|
|
| 35 Pound | 50 Pound | 85 Pound |
|
|
|
|
|
| |
| Cylinder Speeds |
|
|
| ||
|
|
|
|
|
|
|
Gentle wash/reverse speed, RPM |
|
|
| 26 | 26 | 26 |
|
|
|
|
|
|
|
Wash/reverse speed, RPM |
|
|
| 43 | 40 | 41 |
|
|
|
|
|
|
|
Distribution/drain speed, RPM |
|
|
| 77 | 73 | 65 |
|
|
|
|
|
|
|
Medium extract speed, RPM |
|
|
| 325 | 305 | 280 |
|
|
|
|
|
|
|
High extract speed l, RPM |
|
|
| 475 | 445 | 410 |
|
|
|
|
|
|
|
High extract speed 2, RPM |
|
|
| 610 | 575 | 525 |
|
|
|
|
|
|
|
High extract speed 3, RPM |
|
|
| 960 | 900 | 825 |
|
|
|
|
| ||
| Centrifugal Force Data |
|
| |||
|
|
|
|
|
|
|
Gentle wash/reverse centrifugal force, Gs |
|
|
| 0.25 | 0.29 | 0.345 |
|
|
|
|
|
|
|
Wash/reverse centrifugal force, Gs |
|
|
| 0.69 | 0.68 | 0.858 |
|
|
|
|
|
|
|
Distribution/drain centrifugal force, Gs |
|
|
| 2.2 | 2.3 | 2.16 |
|
|
|
|
|
|
|
Medium extract centrifugal force, Gs |
|
|
| 40 | 40 | 40 |
|
|
|
|
|
|
|
High extract 1 centrifugal force, Gs |
|
|
| 85 | 84 | 85.8 |
|
|
|
|
|
|
|
High extract 2 centrifugal force, Gs |
|
|
| 140 | 141 | 141 |
|
|
|
|
|
|
|
High extract 3 centrifugal force, Gs |
|
|
| 345 | 345 | 348 |
|
|
|
|
|
| |
| Balance Detection |
|
|
| ||
|
|
|
|
|
|
|
Vibration safety switch installed |
|
|
| Standard | Standard | Standard |
|
|
|
|
| ||
| Direct Steam Heating (Optional) |
|
| |||
|
|
|
|
|
| |
Steam inlet connection size, mm (in.) |
| DN15 |
| DN15 (0.5) | DN15 (0.5) | DN15 (0.5) |
|
|
|
|
|
|
|
Number of steam inlets |
|
|
| 1 | 1 | 1 |
|
|
|
|
|
|
|
Steam required to raise bath temperature |
| LOW |
| 2.22 (1.6) | 2.91 (2.42) | 3.8 (5.2) |
10° C, kg (10° F, lb.) |
|
|
|
|
|
|
| MED |
| 2.52 (1.81) | 2.42 (3.46) | 4.3 (5.9) | |
|
|
| ||||
|
|
|
|
|
|
|
|
| HIGH |
| 2.84 (2.04) | 2.73 (3.80) | 4.9 (6.9) |
|
|
|
|
|
|
|
Average steam use per cycle, kg (bhp) |
|
|
| 1.47 (23) | 1.95 (30.6) | 54.9 (3.5) |
|
|
|
|
| ||
| Electric Heating (Optional) |
|
| |||
|
|
|
|
|
|
|
Total electric heating capacity, kW |
|
|
| 15.6 | 23.4 | 31.2 |
|
|
|
|
|
|
|
Number of electrical heat elements |
|
|
| 6 | 9 | 12 |
|
|
|
|
|
|
|
Electrical heat element size, kW |
|
|
| 2.6 | 2.6 | 2.6 |
|
|
|
|
|
|
|
Time required to raise bath temperature |
| LOW |
| 3.9 (2.6) | 3.6 (2.4) | 3.1 (4.8) |
10°C, min. (10°F, min.) |
|
|
|
|
|
|
| MED |
| 4.5 (2.9) | 4.2 (2.7) | 3.5 (5.4) | |
|
|
| ||||
|
|
|
|
|
|
|
|
| HIGH |
| 5.0 (3.3) | 4.7 (3.1) | 6.4 (4.1) |
|
|
|
|
|
|
|
F232148 (EN) | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 7 |