Installation/Operation Supplement
SF35PV, SF50PV, SF85PV, UF35PV,
UF50PV, and UF85PV Models
Refer to Table 2.
|
|
|
| 35 Pound | 50 Pound | 85 Pound | |
|
|
|
|
| |||
Overall Dimensions |
|
|
| ||||
|
|
|
|
|
|
| |
Overall width, mm (in.) |
|
| 889 (35) | 990 | (39) | 1181 (46.5) | |
|
|
|
|
|
| ||
Overall height, mm (in.) |
|
| 1407 (55.4) | 1514 (59.6Z) | 1781 (70.1) | ||
|
|
|
|
|
| ||
Overall depth, mm (in.) |
|
| 992 (39) | 1049 (41.3) | 1270 (50) | ||
|
|
|
|
| |||
Weight and Shipping Information |
|
|
| ||||
|
|
|
|
|
| ||
Net weight, kg (lbs.) |
|
| 550 (1212) | 726 (1600) | 1362 (3000) | ||
|
|
|
|
|
| ||
Domestic shipping weight, kg (lbs.) |
|
| 572 (1260) | 749(1650) | 1407 (3100) | ||
|
|
|
|
|
| ||
Domestic shipping volume, m3 (ft3) |
|
| 1.80 (63.6) | 2.26 (80) | 3.46 (123) | ||
Export shipping weight, kg (lbs.) |
|
| 580 (1275) | 1750 | (795) | 3200 (1453) | |
|
|
|
|
|
| ||
Export shipping volume, m3 (ft3) |
|
| 1.85 (65.3) | 2.36 (83.5) | 3.86 (137) | ||
Wash Cylinder Information |
|
|
| ||||
|
|
|
|
|
|
| |
Cylinder diameter, mm (in.) |
|
| 668 (26.25) | 762 | (30) | 914 (36) | |
|
|
|
|
|
|
| |
Cylinder depth, mm (in.) |
|
| 467 (18.375) | 508 | (20) | 61 (240) | |
|
|
|
|
|
| ||
Cylinder volume, l (ft3) |
|
| 164 (5.79) | 232 (8.19) | 400 (14.1) | ||
Perforation size, mm (in.) |
|
| 0.188 (4.77) | 0.188 | (4.77) | 4.77 (0.188) | |
|
|
|
|
|
| ||
Perforation open area, % |
|
| 23 | 23 | 23 | ||
|
|
|
|
| |||
Door Opening Information |
|
|
| ||||
|
|
|
|
|
| ||
Door opening size, mm (in.) |
|
| 354 (13.9) | 413 (16.25) | 445 (17.5) | ||
|
|
|
|
|
| ||
Height of door bottom above floor, mm (in.) |
|
| 636 (25) | 23 (585) | 32.7 (831) | ||
|
|
|
|
| |||
Water Consumption |
|
|
| ||||
|
|
|
|
|
|
| |
Average water consumption per cycle, l (gal.) |
| HOT |
| 47 (178) | 216 | (57) | 407 (108) |
|
|
|
|
|
|
| |
|
| COLD |
| 79 (21) | 98 (26) | 190 (50) | |
|
|
|
|
|
|
|
|
Average hot water consumed per hour, l (gal.) |
|
| 276 (73) | 322 | (85) | 579 (153) | |
|
|
|
|
| |||
Power Consumption |
|
|
| ||||
|
|
|
|
|
| ||
Average power used per cycle, kWh |
|
| 0.4 | 0.6 | 0.9 | ||
|
|
|
|
|
| ||
Average HVAC load, kcal/hr (Btu/hr) |
|
| 125 (500) | 213 (850) | 300 (1200) | ||
|
|
|
|
|
| ||
Nominal sound emission, dBA |
|
| 70 | 76 | 75 | ||
|
|
|
|
|
| ||
Background noise level, dBA |
|
| 54 | 49 | 55 | ||
|
|
|
|
| |||
Drive Train Information |
|
|
| ||||
|
|
|
|
|
| ||
Number of motors in drive train |
|
| 1 | 1 | 1 | ||
|
|
|
|
|
| ||
Drive motor power, kW (HP) |
|
| 2.2 (3) | 3.7 (5.0) | 5.6 (7.5) | ||
|
|
|
|
|
|
| |
Table 2 | (Continued) |
|
|
|
|
6 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232148 (EN) |