Programming

Options for Each Segment

 

 

 

 

 

 

Cycle Steps Available

 

Display

Setting Options for Cycle Steps

(NOTE: WASH, ADD BLEACH,

 

 

 

RINSE and SPIN LEDs light ONLY

 

 

 

when a cycle formula is in

 

 

 

operation.)

 

 

 

 

 

 

 

Wash 1 (displayed as “USH1”)

 

 

 

 

 

Time for Agitation (excludes fill, drain,

 

norn

0 or 2-30 minutes in agitation step (increases/decreases in

spin and heat)

 

 

one-minute increments). Refer to Table 3 for operation of

 

GEnt

 

 

each agitation segment

 

 

 

 

 

 

 

Fill valves (temperature)

 

CFIL

Cold, Hot or Both (warm) water fills or Extra Fill*

 

 

 

 

 

 

HFIL

 

 

 

 

 

 

 

bFIL

 

 

 

 

 

 

 

EFIL

 

 

 

 

 

Fill water level control

 

LO

Low, Medium or High water level

 

 

 

 

 

 

nEd

 

 

 

 

 

 

 

HI

 

 

 

 

 

Supply

 

SUP0

SUP0 for No Supply or Supply 1- 7 (Refer to Table 2 for

 

 

 

operation of each supply selection)

 

 

SUP1

 

 

 

 

 

 

 

 

 

SUP2

 

 

 

 

 

 

 

SUP3

 

 

 

 

 

 

 

SUP4

 

 

 

 

 

 

 

SUP5

 

 

 

 

 

 

 

SUP6

 

 

 

 

 

 

 

SUP7

 

 

 

 

 

Heat (Models with heat or heat capability)

 

HEAt

00F (no heat for segment) or 80oF to 205oF

 

 

 

00C (no heat for segment) or 27oC to 95oC

 

 

noHt

 

 

 

 

 

 

 

Drain (Final segment drains in stop

 

drAI

Drain or No Drain (if No Drain programmed, will skip spin

routine if No Drain is programmed)

 

 

segment associated with Drain segment )

 

nodr

 

 

 

 

 

 

 

Spin time

 

SPIn

00 for No Spin or 30-240 seconds (increases/decreases in

 

 

 

one-second increments)

 

 

tInE

 

 

 

 

 

 

 

Wash 2 (displayed as “USH2”)

 

 

 

 

 

Time for Agitation (excludes fill, drain,

 

norn

0 or 2-20 minutes in agitation step (increases/decreases in

spin and heat)

 

 

one-minute increments). Refer to Table 3 for operation of

 

GEnt

 

 

each agitation segment

 

 

 

 

 

 

 

Fill valves (temperature)

 

CFIL

Cold, Hot or Both (warm) water fills or Extra Fill*

 

 

 

 

 

 

HFIL

 

 

 

 

 

 

 

bFIL

 

 

 

 

 

 

 

EFIL

 

 

 

 

*Extra Fill (EFIL) possible only if international model configured for “EFIL” in SETUP mode.

 

 

Table 1 (Continued)

F232179