When modifying a cycle, a time must be entered for each segment. To skip a segment or spin, set the time to “00” and press the Start key. Table 3 gives the time parameters for each segment and spin, as well as the allowable temperature range.

Time and Temperature Parameters

Function

Minimum

Maximum

 

 

 

PreWash

2 minutes

30 minutes

 

 

 

Wash

2 minutes

20 minutes

 

 

 

Fill 1

2 minutes

15 minutes

 

 

 

Fill 2

2 minutes

15 minutes

 

 

 

Fill 3

2 minutes

15 minutes

 

 

 

Fill 4

2 minutes

15 minutes

 

 

 

Fill 5

2 minutes

15 minutes

 

 

 

Fill 6

2 minutes

15 minutes

 

 

 

Fill 7

2 minutes

15 minutes

 

 

 

Fill 8

2 minutes

15 minutes

 

 

 

Fill 9

2 minutes

15 minutes

 

 

 

Intermediate Spin*

30 seconds

240 seconds

 

 

 

Final Spin**

1 minute

10 minutes

 

 

 

Temperature

75°F (25°C)

200°F (93°C)

 

 

 

*Programmed with wash segment through Fill 8.

**Programmed with Fill 9.

Table 3

NOTE: Spin times in cycle segments 1 – 10 are entered in seconds (30 to 240), and time for final spin in segment 11 is entered in minutes (1 to 10).

1.Press the Up key until the computer display shows the segment to be edited. Press the Start key.

2.Use the Up or Down key to select the desired segment time. Set this value to zero to skip the segment. Press the Start key.

Programming

NOTE: The computer does not count down the remaining cycle time during fills, drains, cool- down, or prior to first achieving the programmed heat temperature when heating. The computer resumes counting down cycle time once the programmed fill level is reached, when the machine has drained, and after a programmed heat temperature is reached.

3.If the temperature-controlled fill setup option is enabled, the display will show “tFIL.” Press the Start key.

4.Use the Up or Down key to select the desired fill temperature. Refer to Table 4 for fill options.

Fill Temperature Options

Display

Fill Type

 

 

CFIL

Cold Fill

 

 

HFIL

Hot Fill

 

 

bFIL

Warm Fill

 

 

AFIL

Auxiliary Fill*

 

 

*This is available only if the “SUP5”/“AFIL” setup option is set to “AFIL.”

Table 4

If the temperature-controlled fill setup option is enabled and a target temperature is set, the selected fill valve(s) will energize for the first three seconds of the segment fill. The computer will then begin operating the fill valves in an attempt to reach the target temperature. Press the Start key.

5.Use the Up or Down key to select the desired fill level. Refer to Table 5.

Water Level Options

Display

 

Fill Level

 

 

 

Lo

 

Low Level

 

 

 

nEd

 

Medium Level

 

 

 

HI

 

High Level

 

 

 

 

Table 5

F232182

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT