Programming

Cycle Segment Charts

 

Segment 1 (PreWash)

 

 

Display

Instructions

 

Use Up or Down key to change. Press Start key to enter or advance.

 

 

 

PrE

 

 

 

00 or 02 to 30

Select segment time: 02 to 30 minutes (00 to skip segment).

 

 

tFIL

Indicates temperature fill is enabled.*

 

 

HFIL, CFIL, bFIL,

Select “HFIL” (hot fill), “CFIL” (cold fill), “bFIL” (warm fill), or “AFIL” (auxiliary fill).**

or AFIL

 

 

 

Lo, nEd, or HI

Select fill level: “Lo” (low), “nEd” (medium), or “HI” (high) water level.

 

 

SUP0 – SUP7

Select supply 0 – 7 (0 for no supply).***

 

 

00°F, 75° – 200°F

Select temperature: 75° to 200°F or 25° to 93°C (00 for no heat).†

00°C, 25° – 93°C

 

 

 

drAI or nodr

Select drain option: “drAI” (drain), “nodr” (no drain).‡

 

 

SPIn (flashed for one second)

tInE (flashed for one second)

00 or 30 to 240

Select time for spin: 30 to 240 seconds (00 for no spin).

 

 

*This is displayed only if temperature-controlled fills are enabled in the setup options and if the heat temperature is set to a value other than “00.”

**“AFIL” can be selected only if the “SUP5”/“AFIL” setup option is set to “AFIL.”

***“SUP5” and “SUP6” can be selected only if the “SUP5”/“AFIL” setup option is set to “SUP5.”

This value is not available when temperature-controlled fill and auxiliary heat setup options are disabled.

‡ If “nodr” is selected, the computer skips the spin step and goes on to the next segment.