Test Cycle

1.Verify that the Run/Program Mode toggle switch is in the Run position.

2.Press the Up or Down key until the display alternately flashes “tESt” and “CYC,” indicating that the test cycle is selected.

3.Press the Start key to begin the test cycle.

NOTE: If “bAL?” or “SPC?” appear on display, ignore it; computer will proceed automatically.

NOTE: Pressing the Start key while the test cycle is in progress will immediately advance to the next step in the test cycle. Drain and load balancing steps may not be skipped.

The test cycle is as follows:

a. Once the Start key is pressed, the door interlock is de-energized (preventing the door from being opened), the drain valve closes, the cylinder begins agitating at wash speed, and both water inlet valves are energized. The display alternately flashes “bFIL” and “Lo” (both hot and cold fill valves on, filling to low level).

b.When the water level switch indicates that low water level has been reached, the water fill valves shut off and the dot above and to the immediate left of the fourth digit of the display lights.

c.The cold water fill valve is energized. The display alternately flashes “CFIL” and “nEd” (cold fill valve on, filling to medium water level).

d.When the water level switch indicates that medium water level has been reached, the cold water fill valve shuts off and the dot above and to the immediate left of the third digit of the display lights.

e.The hot water fill valve is energized. The display alternately flashes “HFIL” and “HI” (hot fill valve on, filling to high water level).

f.When the water level switch indicates that high water level has been reached, the hot water fill valve shuts off and the dot above and to the immediate left of the second digit of the display lights.

Programming

g. The auxiliary heat output is energized, provided that the water level switch indicates that at least low water level is present. The cold water fill valve is energized. The supply 1 output is energized for five seconds. The display alternately flashes “SUP1” and “HEAt” (supply 1 output on, auxiliary heat output on).

h. The supply 2 output is energized for five seconds. The display alternately flashes “SUP2” and “HEAt” (supply 2 output on, auxiliary heat output on).

i. The supply 3 output is energized for five seconds. The display alternately flashes “SUP3” and “HEAt” (supply 3 output on, auxiliary heat output on).

j. The auxiliary heat output is turned off. The supply 4 output is energized for five seconds. The display shows “SUP4” (supply 4 output on).

k. The supply 5/auxiliary fill output energizes for five seconds. If the “SUP5”/“AFIL” setup option is set to “SUP5,” the display shows “SUP5” (supply 5/auxiliary fill output on). If the “SUP5”/“AFIL” setup option is set to “AFIL,” the display shows “AFIL” (supply 5/ auxiliary fill output on).

l. The cold water fill valve turns off. The recirculation pump output is energized for ten seconds, provided that the water level switch indicates that at least low water level is present. The display shows “PUnP” (recirculation pump output on).

m. The motor rotates counterclockwise (in reverse) at normal wash speed for 60 seconds. The display alternately flashes “SLo” and “rEv” (normal wash speed, counterclockwise).

n. The motor rotates clockwise (forward) at normal wash speed for 60 seconds. The display alternately flashes “SLo” and “For” (normal wash speed, clockwise).

o. The motor rotates counterclockwise (in reverse) at normal wash speed for 60 seconds. The display alternately flashes “norn” and “rEv” (normal wash speed, counterclockwise).

F232182

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

19