Operation
Display IndicationsTable 1 through Table 5 list the various displays and what they mean. The operator should become familiar with these computer displays.
Display Indications for
Display | Meaning | Display | Meaning |
|
|
|
|
Program identification code (ROM) | bFIL | Warm fill (both hot and cold) | |
| (this is an example only) |
|
|
|
|
|
|
HoLd | Wait...power has just been turned on | HFIL | Hot fill |
|
|
|
|
CY | Cycle (followed by | LOLE | Low water level |
|
|
|
|
CHEC/CYC* | Test cycle selected | HILE | High water level |
|
|
|
|
FAr | Degrees Fahrenheit | SUP1 | Supply 1 |
|
|
|
|
CEL | Degrees Celsius | SUP2 | Supply 2 |
|
|
|
|
PrE | Prewash segment (1st of 8 segments) | SUP3 | Supply 3 |
|
|
|
|
UASH | Wash segment (2nd of 8 segments) | SUP4 | Supply 4 |
|
|
|
|
FIL1 | First rinse (3rd of 8 segments) | SUP5 | Supply 5 (supply 1 and 2) |
|
|
|
|
FIL2 | Second rinse (4th of 8 segments) | SUP6 | Supply 6 (supply 2 and 3) |
|
|
|
|
FIL3 | Third rinse (5th of 8 segments) | SUP7 | Supply 7 (supply 3 and 4) |
|
|
|
|
FIL4 | Fourth rinse (6th of 8 segments) | STOP | Stop routine |
|
|
|
|
FIL5 | Fifth rinse (7th of 8 segments) | SdLY | Spin coast delay |
|
|
|
|
FIL6 | Sixth rinse (8th of 8 segments) | dOnE | Cycle and stop routine have ended |
|
|
|
|
CFIL | Cold fill | dOOr | Door not properly closed |
|
|
|
|
SPIn/tInE* | Reads “SPIn” for one second, then | FILL/STOP* | Programmed water level not reached after 30 |
| “tInE” followed by time for spin |
| minutes |
|
|
|
|
tSFL | Temperature sensor failure or | FULL | The computer detects low water level or |
| temperature out of range |
| higher when none should be present |
|
|
|
|
*Display indications separated by a slash (/) represent an alternating display.
Table 1
F232137 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9 |