Operation
Display Indications for
Display | Meaning | Display | Meaning |
|
|
|
|
FC 5 | Program identification code (ROM) | HFIL | Hot fill |
| (this is an example only) |
|
|
| Lo | Low water level | |
|
| ||
|
|
|
|
HoLd | Wait...power has just been turned on | nEd | Medium water level |
|
|
|
|
PAY/(price)* | Pay (flashes alternately with start price if | HI | High water level |
| “FLSH” SETUP option is enabled) |
|
|
| SUP0 | No supplies | |
|
| ||
|
|
|
|
CYXX | Cycle (followed by | SUP1 | Supply 1 |
|
|
|
|
tESt/CYC* | Test cycle selected | SUP2 | Supply 2 |
|
|
|
|
FAr | Degrees Fahrenheit | SUP3 | Supply 3 |
|
|
|
|
CEL | Degrees Celsius | SUP5 | Supply 5 (supply 1 and 2) |
|
|
|
|
HEAt | Auxiliary heat enabled | SUP6 | Supply 6 (supply 2 and 3) |
|
|
|
|
noHt | Auxiliary heat disabled | drAI/dISt* | Distribution (load balancing before extract) |
|
|
| |
|
|
|
|
|
| drAI/For* | Drain step (low speed forward in test cycle) |
|
|
|
|
Strt/Ant* | Start amount – flashes briefly before | SPIn/tInE* | Reads “SPIn” for one second, then “tInE” |
| showing vend price in SETUP Mode |
| followed by time for spin |
|
|
| |
|
|
|
|
|
| SdLY | Spin coast delay |
|
|
|
|
Con1/deno* | Coin 1 value – flashes briefly before | STOP | Stop routine |
| showing value of coin 1 in SETUP Mode |
|
|
| donE | Cycle and stop routine have ended | |
|
|
|
|
Con2/deno* | Coin 2 value – flashes briefly before | HI 1 | Low spin in test cycle |
| showing value of coin 2 in SETUP Mode |
|
|
| HI 2 | High spin in test cycle | |
|
|
|
|
PrE | Prewash segment (1st of 8 segments) | bAL/FAIL* | Balance routine failed during test cycle |
|
|
|
|
UASH | Wash segment (2nd of 8 segments) | SHUT/door* | Door not properly closed |
|
|
|
|
FIL1 | First fill (3rd of 8 segments) | CANt/OPEN* | Computer cannot unlock door after five |
|
|
| attempts |
FIL2 | Second fill (4th of 8 segments) |
| |
|
| ||
|
|
|
|
FIL3 | Third fill (5th of 8 segments) | FILL/STOP* | Programmed water level not reached after |
|
|
| 30 minutes |
FIL4 | Fourth fill (6th of 8 segments) |
| |
|
| ||
|
|
|
|
FIL5 | Fifth fill (7th of 8 segments) | FULL | The computer detects low water level or |
|
|
| higher when none should be present |
FIL6 | Sixth fill (8th of 8 segments) |
| |
|
| ||
|
|
|
|
AFIL | Auxiliary fill | dFLt | Drive fault detected |
|
|
|
|
bFIL | Warm fill (both hot and cold) | tSFL | Temperature sensor failure or temperature |
|
|
| out of range |
CFIL | Cold fill |
| |
|
| ||
|
|
|
|
bLCH | Add bleach (for supply 2 only) | bAL? | Special factory balance SETUP Mode |
|
|
|
|
1Pr | One vend price – all cycles | SPC? | Special factory Valve Flush Mode |
|
|
|
|
16Pr | 16 vend prices – one per cycle | SPIN | Spin in test cycle (2 speed only) |
|
|
|
|
CHEC/CYC* | Test cycle selected (same as tESt/CYC) | rEv | Reverse wash speed in test cycle |
|
|
|
|
For | Wash speed forward in test cycle |
|
|
|
|
|
|
FrEE | “Free” cycle option |
|
|
|
|
|
|
*Display indications separated by a slash (/) represent an alternating display.