Operation
Display Indications for
Display | Meaning | Display | Meaning |
|
|
|
|
FP 1 | Program identification code (ROM) | nEd | Medium water level |
| (this is an example only) | HI | High water level |
|
| ||
|
|
|
|
HoLd | Wait...power has just been turned on | SUP1 | Supply 1 |
|
|
|
|
CY | Cycle (followed by | SUP2 | Supply 2 |
|
|
|
|
tESt/CYC* | Test cycle selected | SUP3 | Supply 3 |
|
|
|
|
FAr | Degrees Fahrenheit | SUP4 | Supply 4 |
|
|
|
|
CEL | Degrees Celsius | SUP5 | Supply 5 (Setup option) |
|
|
|
|
HEAt | Auxiliary heat enabled | SUP6 | Supply 6 (supply 1 and 5) |
|
|
|
|
noHt | Auxiliary heat disabled | SUP7 | Supply 7 (supply 3 and 4) |
|
|
|
|
tFIL | SLo/For | Gentle wash speed, forward direction | |
|
|
|
|
ntFL | SLo/rEv | Gentle wash speed, reverse direction | |
|
|
|
|
CooL | Automatic | norn/For | Normal wash speed, forward direction |
noCL | Automatic | norn/rEv | Normal wash speed, reverse direction |
Ag 1 | Agitation 1 selected (90% agitation) | drAI | Drain enabled |
|
|
|
|
Ag 2 | Agitation 2 selected (33% agitation) | nodr | Drain disabled |
|
|
|
|
Ag 3 | Agitation 3 selected (10% agitation) | dISt | Distribution (load balancing before extract) |
|
|
|
|
Ag 4 | Agitation 4 selected (6.7% agitation) | SPIn/tInE* | Reads “SPIn” for one second, then |
|
|
| “tInE” followed by time for spin |
AgSn | Agitation speed normal |
| |
AgSL | Agitation speed low | SPn1 | Lowest of three spins |
|
|
|
|
PUnP | Pump output enabled (future use only) | SPn2 | Middle of three spins |
nPnP | Pump output disabled (future use only) | SPn3 | Highest of three spins |
PrE | Prewash segment (1st of 11 segments) | STOP | Stop routine |
|
|
|
|
UASH | Wash segment (2nd of 11 segments) | SdLY | Spin coast delay |
|
|
|
|
FIL1 | First fill (3rd of 11 segments) | dOnE | Cycle and stop routine have ended |
|
|
|
|
FIL2 | Second fill (4th of 11 segments) | dFLt | Drive fault detected |
|
|
|
|
FIL3 | Third fill (5th of 11 segments) | dOOr | Door not properly closed |
|
|
|
|
FIL4 | Fourth fill (6th of 11 segments) | bAL/FAIL* | Balancing routine failed during test cycle |
|
|
| after 10 attempts to balance load |
FIL5 | Fifth fill (7th of 11 segments) |
| |
|
| ||
|
|
|
|
FIL6 | Sixth fill (8th of 11 segments) | FILL/STOP* | Programmed water level not reached after 30 |
|
|
| minutes |
FIL7 | Seventh fill (9th of 11 segments) |
| |
|
| ||
|
|
|
|
FIL8 | Eighth fill (10th of 11 segments) | FULL | The computer detects low water level or |
|
|
| higher when none should be present |
FIL9 | Ninth fill (11th of 11 segments) |
| |
|
| ||
|
|
|
|
CFIL | Cold fill | rotA | Computer detects possible rotation of motor |
|
|
| when there should be none |
bFIL | Warm fill (both hot and cold) |
| |
|
| ||
|
|
|
|
HFIL | Hot fill | tSFL | Temperature sensor failure or temperature |
|
|
| out of range |
AFIL | Auxiliary fill (Setup option) |
| |
|
| ||
|
|
|
|
Lo | Low water level |
|
|
|
|
|
|
*Display indications separated by a slash (/) represent a flashing display.
Table 4
12 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232137 |