Installation
Electrical Requirements(240 Volt, 50 Hertz with 3 Prong Earthing Plug)NOTE: The wiring diagram is located in the control hood.WARNING
To reduce the risk of fire, electric shock or personal injury, all wiring and earthing MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, and such local regulations as might apply. It is the customer’s responsibility to have the wiring, fuses and circuit breakers checked by a qualified electrician to make sure your home has adequate electrical power to operate the washer.
W129
DO NOT OVERLOAD CIRCUITS
DO NOT USE ADAPTER
D009I
DO NOT USE AN EXTENSION CORD
D009I
Figure 16
WARNING
Improper connection of the equipment- earthing conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the washer is properly earthed.
W218
Do not modify the plug provided with the washer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
STANDARD
240 VOLT, 50 HERTZ,
3 WIRE EFFECTIVELY
EARTHED CIRCUIT
0 VOLT | 240 VOLTS | |
50 HERTZ | ||
|
240 VOLTS
50 HERTZ
Earthing Instructions
The washer must be earthed. In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least
2
1
W504S
resistance for electric current. The washer is equipped with a cord having an
1Power Cord
2Earth (Ground) Prong
Figure 17
14 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 38910 |