Water Supply Requirements

WARNING

Under certain conditions, hydrogen gas may be produced in a hot water system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE. If the hot water system has not been used for such a period and before using the washer, turn on all hot water faucets and let the water flow from each for several minutes. This will release any accumulated hydrogen gas. The gas is flammable. Do not smoke or use an open flame during this time.

W029

NOTE: Water supply faucets must fit standard 3/4 -14 BSP metric female couplings. DO NOT USE SLIP-ON OR CLAMP-ON CONNECTIONS.

NOTE: Water supply faucets should be readily accessible to permit turning them off when washer is not being used.

1

2

WATER

MIXING

VALVE

C

H

4

3

W187I

1Water Supply Faucets

2Cold Water Connection

3Hot Water Connection

4Fill Hoses

Figure 18

Installation

Water Temperature

Cold:

Recommended cold water temperature is 10° to 24° Celsius (50° to 75° Fahrenheit).

Hot:

Recommended hot water temperature is 60° to 66° Celsius (140° to 150° Fahrenheit).

Warm:

Mixture of hot and cold water. (Warm water temperature is dependent upon the water temperature and the pressure of both the hot and cold water supply lines.)

IMPORTANT: Turn off water supply faucets after check-out and demonstration. Owner should turn off water supply whenever there will be an extended period of non-use.

NOTE: A longer fill hose is available (as optional equipment at extra cost) if the hose (supplied with the washer) is not long enough for the installation. Order hose as follows:

Part Number WA003 – 2,5 m Inlet Hose