3.Verify
| 1 |
|
2 | 3 | 5 |
|
| 4 |
P045I
1Drive Motor
2Drive Pulley
3Belt
4Straight Edge
5Drive Pulley
Figure 4
4.Remove back panel and check all hoses for leaks, cracking and deterioration.
5.Open machine top cover and check supply dispenser hoses and hose connections for leaks.
6.Remove front service panel. Check all hoses and temperature probe for leaks, cracking and deterioration.
Maintenance
7.Clean inlet hose filter screens:
a.Turn water off and allow valve to cool, if necessary.
b.Unscrew inlet hose and remove filter screen.
c.Clean with soapy water and reinstall. Replace if worn or damaged.
8.Make sure that all hose clamps are tight and all hoses are secure
9.Tighten motor mounting bolt locknuts and bearing bolt locknuts, if necessary.
10.Verify that motor plate mounting bolt is tight but plate is free to pivot.
11.Use compressed air to clean dust and lint from motor.
12.Clean interior of
13.Open rear electrical enclosure and clean out any dust or lint build up in box with a vacuum cleaner and a soft brush. Lint
WARNING
Do not clean the cooling fans with compressed air! Doing this spins the fan too fast and will cause premature fan failures.
W695
14.Remove chemical supply components and check for residual chemicals. Clean as necessary and replace.
F8112201 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 17 |