Installation

5

30°

1

2

2

A B C D E F G H I J K

1

3

AIR

FLOW

 

EXHAUST AIR FLOW

 

 

4

 

 

 

MAXIMUM LENGTH OF

 

 

 

 

 

DUCT 30 feet (9.1 m)

 

 

 

EXHAUST

 

 

 

OUTLET

 

HORIZONTAL EXHAUST INSTALLATION

 

 

 

 

 

 

H318I

NOTE: Where the exhaust duct pierces a

3

Clearance per Local Codes

 

combustible wall or ceiling, the opening must be

4

No Screen or Cap

 

sized per local codes.

5

Clean Out Cover – Inspect Monthly

 

Wall

 

 

 

 

 

Figure 26

.

2

1

CONNECT TO DRYER

3

4

VERTICAL EXHAUST INSTALLATION

H319I

1Roof

2Wall

32" (5 cm) Minimum

4NOTE: Where the exhaust duct pierces a combustible wall or ceiling, an opening must be sized as shown or per local codes.

Figure 27

WARNING

To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.

W045

Duct Station

Minimum Diameter of

Collector Duct

 

 

 

A

4 inches (10.2 cm)

 

 

B

8 inches (20.3 cm)

 

 

C

9 inches (22.9 cm)

 

 

D

10 inches (25.4 cm)

 

 

E

11 inches (27.9 cm)

 

 

F

12 inches (30.5 cm)

 

 

G

13 inches (32.6 cm)

 

 

H

14 inches (35.6 cm)

 

 

I

15 inches (38.1 cm)

 

 

J

15 inches (38.1 cm)

 

 

K

16 inches (40.6 cm)

 

 

510975

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

39