NOTE: Some models come without an electrical plug installed. If washer is not hard wired (refer to Figure 19), a suitable plug that meets local electrical standards, including earthing requirements, must be installed. Refer to the washer nameplate for proper voltage and Hertz the washer is designed to operate on. Refer to Figure 18.
WARNING
To reduce the risk of electric shock or fire, DO NOT use an extension cord or an adapter to connect the washer to the electrical power source.
W031
120 Volt/50 Hertz
This washer is designed to be operated on a separate polarized
50 Hertz,
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
240 Volt/50 Hertz
This washer is designed to be operated on a separate polarized
50 Hertz,
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
230 Volt/50 Hertz
This washer is designed to be operated on a separate polarized
50 Hertz
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
Installation
1
W334I
1Nameplate
Figure 18
240 Volt/60 Hertz
This washer is designed to be operated on a separate polarized
10ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THE WASHER IS OPERATING.
Earthing (Grounding) Instructions
The washer must be earthed (grounded). In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. The washer is equipped with a cord having an
WARNING
Improper connection of the equipment- earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the washer is properly earthed.
W032
Do not modify the plug provided with the washer — if it will not fit the outlet, have a proper outlet installed by a qualified electrician.