LEDs on AT-8600 Series Switches

The following tables outline how the switch and expansion modules report faults and operational activities. Expansion modules are optional and can be purchased separately. Contact an authorised Allied Telesis distributer or reseller, or visit www.alliedtelesis.com for more information on purchasing expansion modules.

System LEDs

LED

State

Description

FAULT

Off

Switch operation is normal.

 

 

 

 

Red

The switch or management software is

 

 

malfunctioning.

 

 

 

 

1 flash

A switch fan has failed.

 

 

 

 

3 flashes

The main PSU has failed and the RPS is now

 

 

providing power.

 

 

 

 

4 flashes

The RPS Monitor is set to ON, and the RPS

 

 

is not functioning, either because it has failed

 

 

or has been switched off.

 

 

 

 

5 flashes

The RPS Monitor is set to ON, but the RPS

 

 

is not connected.

 

 

 

 

7 flashes

For the AT-8624T/2M and AT-8624PoE

 

 

switches: An expansion module has been

 

 

inserted or removed while the switch is

 

 

powered on.

 

 

MASTER

This LED is not supported and will never be lit.

 

 

 

RPS

Green

An optional redundant power supply is

 

 

connected to the switch.

 

 

 

 

OFF

There is no optional redundant power

 

 

supply connected to the switch.

 

 

 

PWR

Green

The switch is receiving power and the

 

 

voltage is within the acceptable range.

 

 

 

 

Off

The switch is not receiving power.

 

 

 

Note Use the Mode Select button to toggle the Mode LEDs to the desired state. Toggling the Mode Selection button does not affect the normal operations of the switch.