Allied Telesis AR44xS series manual CR00011665, CR00011746, CR00011780, CR00011809, CR00011844

Models: AR44xS series

1 84
Download 84 pages 45.04 Kb
Page 35
Image 35

 

 

 

 

 

 

 

Features in 276-02

 

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

Module

Level

Description

AR44xS / AR450S

AR7x5

AR750S

 

Rapier i

AT-8800

AT-8600

 

AT-8700XL

AT-8948

AT-9900

AT-9800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00011665

PRI

2

When using an unstructured TDM group over an E1 mode PRI interface,

Y

Y

Y

 

Y

-

-

 

-

-

-

-

 

 

 

occasionally a high level of errors was experienced. This may have caused the link

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to be unstable, or may have resulted in reduced data throughput.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00011746

BGP

2

If the router or switch failed to establish a BGP peer session because of

Y

Y

Y

 

Y

Y

-

 

-

Y

Y

Y

 

 

 

unsuccessful Open message exchanges, no further attempts to establish the peer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection were made.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. The router or switch now continues to attempt to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

establish the session, with 60 second intervals between attempts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00011780

BOOTP

2

Previously, if a user entered the command set bootp relay option82

Y

Y

Y

 

Y

Y

Y

 

Y

Y

Y

Y

 

 

 

port=portnum without also specifying one of the required subscriberid or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

trusted parameters, the router or switch would incorrectly report “Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Successful”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. The router or switch now reports that one of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parameters subscriberid or trusted must also be specified as part of this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00011809

Firewall

2

The SIP application layer gateway (ALG) did not correctly handle SIP packets that

Y

Y

Y

 

Y

Y

-

 

-

-

-

Y

 

 

 

had an extension parameter added to the “From” field. In VoIP networks that

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

added this extension parameter, users telephoning out from the private network

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

could not hear the recipient talk, because the VoIP voice data was not passed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from the remote client to the client on the private side.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00011844

IPv6

2

IPv6 interfaces did not work over a PPP link on switches or AR44x routers. When

Y

-

-

 

Y

Y

-

 

-

Y

Y

Y

 

 

 

the interface received IPv6 traffic, the router or switch rebooted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 276-05

C613-10474-00 REV D

Page 35
Image 35