Features in 276-04

 

 

 

9

Level 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

Module

Level

Description

AR44xS/ AR450S

AR7x5

AR750S

 

Rapier i

AT-8800

AT-8600

 

AT-8700XL

AT-8948

AT-9900

AT-9800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00009079

MLD

2

When MLD snooping creates an All Router group, it also (correctly) adds router

-

-

-

 

Y

Y

-

 

-

-

-

-

 

Snooping,

 

ports to other groups. However, when MLD Snooping detected that there were

 

 

 

 

 

 

 

 

 

 

 

 

 

IPv6, Switch

 

no more router ports in the network, it deleted the All Router group but did not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

delete the router ports from the other groups.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00009212

Bridge

2

The Bridge cannot be configured to bridge PPPoE packets from an Ethernet

Y

-

Y

 

-

-

-

 

-

-

-

-

 

 

 

interface that has also been configured as a PPPoE interface. Previously, such a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bridge configuration would appear to succeed. However the Bridge would not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bridge PPPoE packets and the router would restart when the command reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bridge was entered.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. Note: if you want to bridge PPPoE packets, do not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

also configure the router as a PPPoE endpoint (by using the command create

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ppp=number over=ethx-any).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00009213

MSTP

2

Because of an MSTP issue, the switch did not always send a BPDU with an

-

-

-

 

Y

Y

Y

 

Y

-

-

-

 

 

 

agreement flag to its designated bridge, even if the switch was synchronised with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the latest spanning tree information from the designated bridge. This prevented

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the designated port on the designated bridge from making a fast transition to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the forwarding state. The result was that the network could take up to two times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the “forward delay” time to fully converge.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00009826

IP Gateway

2

When a static ARP is deleted, the router or switch sends out an ARP request to

Y

-

Y

 

Y

Y

Y

 

Y

-

-

-

 

 

 

attempt to create a dynamic ARP for that IP address. Previously, the router or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch did not process the ARP response correctly and therefore did not add the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ARP to its ARP table.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. When a static ARP is deleted, the router or switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

attempts to create a dynamic ARP for that IP address, and will successfully add it

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the ARP table if a device responds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 