Table 7 contains the cabling specifications for the twisted pair ports.

Table 7. Twisted Pair Cabling and Distances

 

 

Maximum

Speed

Type of Cable

Operating

 

 

Distance

 

 

 

 

 

 

10 Mbps

Category 3 or better 100-ohm shielded or

100 m (328 ft)

 

unshielded twisted pair cable

 

 

 

 

100 Mbps

Category 5 or Category 5E (Enhanced) 100-

100 m (328 ft)

 

ohm shielded or unshielded twisted pair cable

 

 

 

 

1000 Mbps

Category 5 and Category 5E (Enhanced) 100-

100 m (328 ft)

 

ohm shielded or unshielded twisted pair cable

 

 

 

 

Note

The twisted pair ports on the switch feature auto-MDI when operating at 10, 100 or 1000 Mbps. Each port is individually configured as MDI or MDI-X when connected to an end node. Consequently, you can use either a straight-through or crossover twisted pair cable when connecting any network device to a twisted pair port on the switch.