Features in 281-01

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

Module

Level

Description

AR400

AR7x5

AR750S / AR770S

 

Rapier i

AT-8800

AT-8600

 

AT-8700XL

AT-8948 / x900-48

AT-9900

AT-9800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00013049

IPv6

3

The router or switch sometimes rebooted when it processed a large number of

Y

Y

Y

 

Y

Y

-

 

-

Y

Y

Y

 

 

 

multicast routes that were created as the result of receiving a large amount of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

data from more than 500 multicast groups.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00013085

OSPF

3

A user can configure a range on an OSPF ABR, so that the ABR aggregates the

Y

Y

Y

 

Y

Y

Y

 

Y

Y

Y

Y

 

 

 

network advertisements from one area into another area in the form of summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LSAs. However, networks advertised into a transit area should not be aggregated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

into summary LSAs. Previously, the router or switch advertised aggregated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

summary LSAs into transit areas when a range had been configured.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. When the router or switch is advertising into a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

transit area, it ignores any configured range.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00013093

Switch

3

When traffic on a port was mirrored and that port had a learn limit set, packets

-

-

-

 

Y

Y

Y

 

Y

-

-

-

 

 

 

from the CPU (such as ARP replies and ICMP replies) were not always mirrored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00013190

Core

3

If a AT-8624PoE switch had a sticky fan, the fan constantly toggled between

-

-

-

 

-

-

Y

 

-

-

-

-

 

 

 

running at full speed and slowing down. This meant that the fan continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

generated alarms.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. If the fan reports an error more than 3 times in an

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hour, it now remains at its maximum speed setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00013202

Core

3

On the AT-8624PoE switch, a fan fault alarm was not generated when the fan

-

-

-

 

-

-

Y

 

-

-

-

-

 

 

 

speed dropped to 70% of the expected speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. When the speed drops to 70% or less, a alarm is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

now generated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 281-01

C613-10482-00 REV A

Page 16