MATRIX SWITCHERS

Press the RECALL button and hold for 2 seconds. The unit will beep and switch into the recall mode. This mode is indicated by the RECALL LED flashing slowly. Press INPUT 1 through INPUT 16 to recall the desired memory location. Output buttons do not work anymore in this operation.

Press and hold the RECALL button for 2 sec. again to disable the recall function.

Disable/Enable Front Panel:

Press the OUT SEL button and hold it for 2 seconds. The front panel will be disabled. Press and hold it again to enable the front panel.

Preview of Connection

When any output is selected through the Front Panel CP-01buttons, the input/inputs that are connected to that particular output will show its LED ON. Similarly if any input is selected on the Front Panel CP-01, then the output to outputs connected to this input will show a flashing LED.

PROGRAMMING OPERATION

This programming operation is only performed for changing module settings and should not be part of a general control operation. All the HOMERUN modules that are connected through a loop cable to the HOMERUN Switcher module with a CP-01Front Panel will be reprogrammed.

Enable Vertical interval switching:

This function operates only if the VIS function is installed. Press the SETUP button. The SETUP LED will start to flash. Press OUT 7 to enable the VIS function. The VIS function operates only with NTSC or PAL type video signals. Input #1 is the reference input for the purposes of VIS switching. If Input #1 is not present the HOMERUN will switch without VIS even though VIS is enabled.

Disable vertical interval switching:

This function operates only if the VIS function is installed. Press the SETUP button. The SETUP LED will start to flash. Press OUT 8 to disable the VIS function.

Set Unit ID numbers

This function is used to control individual levels of the HOMERUN Matrix Switcher, such as switching video and audio separately. If the HOMERUN Switcher is set to unit ID 1 then the switcher will respond to all commands through the RS-232 port regardless of the UID command. The factory default is unit ID =1.

To set the unit ID number, press the SETUP button. The SETUP LED will start to flash. Press the OUT1 through OUT6 buttons to select the proper unit ID number. The switcher will reset after this operation.

This command will set unit ID numbers on the master unit and also on all units attached to the master unit.

Therefore only the units that need to have changes in unit ID number should be attached to the master unit during the set-up phase through the loop cable.

Suggested Unit ID assignment if individual control is required:

Unit ID 2 Red, Green and Blue channels (All three channels should have the same Unit ID number)

Unit ID 3 Horizontal, Vertical or Composite sync channels (All sync channels should have the same Unit ID number)

Unit ID 4 Composite video signal channel

Unit ID 5 S-Video type video signal channels (Both Luma and Chroma should have the same Unit ID numbers)

Unit ID 6 Left and right audio channels should have the same Unit ID numbers.

SETUP +OUT 1

UNIT ID #1

 

 

SETUP +OUT 2

UNIT ID #2

 

 

SETUP +OUT 3

UNIT ID #3

 

 

SETUP +OUT 4

UNIT ID #4

 

 

SETUP +OUT 5

UNIT ID #5

 

 

SETUP +OUT 6

UNIT ID #6

 

 

17

Page 18
Image 18
Altinex 400-0026-004 manual Programming Operation