MATRIX SWITCHERS

 

ACCESSORIES

8

 

 

 

 

 

Model No.

Description

 

 

 

 

 

 

 

RACK MOUNTING BRACKETS

 

 

DA1292RM

19”-1U Rack mount ears for rack

 

 

 

wide units

 

 

 

TABLE MOUNT BRACKETS

 

 

TM1277

3U High, 1 Rack-Wide

 

 

 

4 BNC TO 4 BNC COAXIAL CABLE

2

3

My modules do not communicate with each other?

Can I control multiple switchers with

When you experience lack of communication check the following:

1.Cable connections.

2.Unit ID settings.

3.Same Baud rate settings.

Yes. You can control up to 14 different groups of switchers. Just connect the

CB4100MR

CB4106MR

CB4112MR

CB4125MR

CB4150MR

CB4175MR

CB41100MR

CB4200MR

CB4206MR

CB4212MR

CB4225MR

CB4250MR

CB4275MR

CB42100MR

CB4300MR

CB4400MR

Bulk cable 4 coaxes (500 ft minimum)

6feet

12feet

25feet

50feet

75feet

100feet

5BNC TO 5 BNC COAXIAL CABLE Bulk cable 4 coaxes (500 ft minimum)

6feet

12feet

25feet

50feet

75feet

100feet

4 BNC TO 4 BNC COAX (Super High Res.)

Bulk cable 4 coaxes (500 ft minimum)

5 BNC TO 5 BNC COAX (Super High Res.)

Bulk cable 5 coaxes (500 ft minimum)

OPTIONAL CONTROL ACCESSORIES

4

5

one RS-232 card?

Does the

HOMERUN come with the rack mounts?

How does one increase the number of inputs or number of outputs on the switcher?

Loop out port to the next switcher’s Loop in port using provided cables.

Yes, two 1-U high rack mounts are included with each module. Please check the packaging carefully.

To increase the number of inputs one can add second switcher and loop some of the outputs (say 8) of the first switcher to the 8 inputs of the second switcher, thus creating a 24x8 Matrix Switcher. To increase the number of outputs use a second switcher and a VA6834FC interface with dual output, or 1 in 2 out DA at each of the inputs. This will increase the matrix size to 16x32. For other

 

CP-01

Front Panel control

 

 

CP-02

Remote control pad w/cable

 

 

CP-03

Touch screen LCD Display control

 

 

 

panel w/cable

 

 

 

 

 

FAQ (Frequently Asked Questions)

9

6

Can I switch each module independently?

configurations call Altinex.

Yes. Using proper RS-232 commands, one can control each level of switching independently by assigning a unique ID

No:

1

Question

How do I know what input is connected to what output?

Answer

This information must be maintained by the control system. The present version of the software does not track that information.

7

If I need to use a switcher to switch

RGBHV,

Composite Video, S-Video and/or Audio

number

Yes, the HOMERUN Switcher can switch RGBHV, Composite Video, S-Video and/or Audio at the same time.

Contact Altinex if you have

21

Page 22
Image 22
Altinex 400-0026-004 manual Accessories, Rack Mounting Brackets, Table Mount Brackets, BNC to 4 BNC Coaxial Cable