MULTI-TASKER™

The Group ID is a number representing a group of cards defined with the [WR] command. When using the Group ID, all cards in the group will perform the given instruction.

Changing the position of a card will significantly affect the commands recorded on software definitions or third party control systems.

The Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to zero, each command may be used without Ui. Use the command [SETU0], as explained in the MT100-100 User’s Guide.

Example:

[VERC3]: For Unit ID Zero

[VERC3Ui]: For Unit ID other than Zero

[VERC3]: Equivalent to [VERC3U0]

1.[VER]

This command displays the software version and model for the MT105-100/101card.

Command Format: [VERCnUi]

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

There is an MT105-100in slot 4. Send the command [VERC4] and receive the following feedback:

[MT105-100 690-0126-014 C04]

MT105-100

= Card Model Number

690-0126-016

= Software Version

C04

= Card ID

2. [C]

This command displays the status of the card and connections of the matrix switcher.

Command Format: [CnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

An MT105-100/101card is in slot 2, Input 1 is connected to all outputs and outputs 1, 2 and 3 are on. Send the command [C2] and receive the following feedback:

Matrix:16X8

In01-Out1 ON

In01-Out2 ON

In01-Out3 ON

In01-Out4 OFF

In01-Out5 OFF

In01-Out6 OFF

In01-Out7 OFF

In01-Out8 OFF

NOTE: If there is no card in slot 2, sending the command [C2] will not return any feedback.

3.[CnS]

This command saves the input to output settings as well as the output enable status. This configuration will be restored after the system is reset or powered off then on.

Command Format: [CnSUi]

Cn = Card ID (n = # from 1 to max slots)

S = save configuration

Ui = Unit ID (i = # from 0 to 9)

Example:

Input 1 is connected to all 8 outputs, but only 1 through 4 are on. Send the command [C4S] for slot 4, and receive the following feedback:

Matrix:16X8

In01-Out1 ON

In01-Out2 ON

In01-Out3 ON

In01-Out4 ON

In01-Out5 OFF

In01-Out6 OFF

In01-Out7 OFF

In01-Out8 OFF

[SAVEDC04]

400-0131-004

9

9

Page 10
Image 10
Altinex MT105-100, MT105-101 manual Ver, CnS, SAVEDC04