12.[…P] – PATH
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See the examples in [ON] and [OFF] commands.
Example:
There is an
The notation "P=" at the end of the line indicates the path condition is active. "P=2" on the Output 1 line indicates that after the [SW] command, Input 2 will be connected to Output 1.
The notation "P=OFF" on lines 2 and 3 indicates that Outputs 2 and 3 will be turned off after the [SW] command is executed.
13.[SW] – SWITCH
This command immediately connects inputs and outputs previously set with the path command. The command switches all paths set on this card and all other cards in the enclosure.
13 |
Example:
The following commands set the path for turning on Output 1 of the card in slot 6 and turning off Output 3 of the card in slot 9. Nothing happens until the [SW] command is sent. At that time, Output 1 will be enabled and Output 3 will be disabled.
[ON1C6P] , [OFF3C9P] and [SW]
14.[ImOx]
This command connects a single input to a single output in the current matrix configuration.
Command Format: [ImOxCnUi]
m= Input (m= # from 1 to 16) x = Output (x = # from 1 to 8)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Connect Input 1 to Output 1 for the
15.[ImO*]
This command connects a single input to all the outputs in the current matrix configuration.
Command Format: [ImO*CnUi]
m | = Input (m = # from 1 to 16) |
Cn | = Card ID (n = slot # from 1 to max slots) |
Ui | = Unit ID (i = # from 0 to 9) |
Example:
Connect Input 1 to all outputs for the
16.[CLR]
This command performs a reset of the card and restores settings to the factory defaults.
Command Format: [CLRCnUi]
Cn | = Card ID (n = # from 1 to max slots) |
Ui | = Unit ID (i = # from 0 to 9) |
13