MULTI-TASKER

5.[HPOSnCi] - Set Value

This command sets the Horizontal Position to an absolute value. It also makes the Horizontal Position adjustment the active control.

Command Format: [HPOSnCiUy]

n = a value from 0 to 20

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 7 of unit ID 4. Set the Horizontal Position to the maximum value of 20 by sending the command [HPOS20C7U4].

6.[HPOSCi] - Status/Adjust

This command selects the Horizontal Position adjustment and makes it the active control. It is also used to return the status of the current Horizontal Position. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [HPOSCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 4 of unit ID 1. View the current Horizontal Position and make Horizontal Position the active control.

[HPOSC4U1] 10

[HPOSC4U1]

= STATUS command

10

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

7.[VPOSnCi] - Set Value

This command sets the Vertical Position to an absolute value and makes the Vertical Position adjustment the active control.

Command Format: [VPOSnCiUy]

n = a value from 0 to 20

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 2 of unit ID 3. Set the Vertical Position to the value of 12 by sending the command [VPOS12C2U3].

8.[VPOSCi] - Status/Adjust

This command selects the Vertical Position adjustment and makes it the active control. It also returns the status of the current Vertical Position. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [VPOSCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 2 of unit ID 3. View the current Vertical Position and make Vertical Position the active control.

[VPOSC2U3] 10

[VPOSC2U3]

= STATUS/Current value

10

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

9.[HSIZEnCi] - Set Value

This command sets the Horizontal Size to an absolute value and makes the Horizontal Size adjustment the active control.

Command Format: [HSIZEnCiUy]

n = a value from 0 to 20

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

9

Page 10
Image 10
Altinex MT106-100 HPOSnCi Set Value, Command Format HPOSnCiUy, HPOSCi Status/Adjust, HPOSC4U1, VPOSnCi Set Value, VPOSC2U3