MULTI-TASKER

Zoom value. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [QZOOMCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 2 of unit ID 3. View the current Quadrant Zoom value and make Quadrant Zoom the active control.

[QZOOMC2U3] 0

[QZOOMC2U3]

= STATUS/Current value

0

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

The zoom value will cycle through all five values repeatedly when using the [ + ] and [ - ] controls. For example, when the zoom value is at 4 and the increment command is sent, the next zoom value will be 0.

15. [BRIGnCi] - Set Value

This command sets the Brightness to an absolute value and makes the Brightness adjustment the active control.

Command Format: [BRIGnCiUy]

n = a value from 1 to 4

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 4 of unit ID 2. Set the Brightness to the value of 2 by sending the command [BRIG2C4U2].

16. [BRIGCi] - Status/Adjust

This command selects the Brightness adjustment and makes it the active control. It also returns the status of the current Brightness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [BRIGCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 2 of unit ID 3. View the current Brightness and make Brightness the active control.

[BRIGC2U3] 2

[BRIGC2U3]

= STATUS/Current value

2

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

17. [SHARPnCi] - Set Value

This command sets the Sharpness to an absolute value. It also makes the Sharpness adjustment the active control.

Command Format: [SHARPnCiUy]

n = a value from 1 to 8

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-100 in slot 4 of unit ID 2. Set the Sharpness to the value of 2 by sending the command [SHARP2C4U2].

18. [SHARPCi] - Status/Adjust

This command selects the Sharpness adjustment and makes it the active control. It is also used to return the status of the current Sharpness level. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [SHARPCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

11

Page 12
Image 12
Altinex MT106-100 manual QZOOMC2U3