MULTI-TASKER
11
Zoom value. As the active control, it may be
adjusted using the [ + ] and [ - ] commands.
Command Format: [QZOOMCiUy]
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 2 of unit ID 3.
View the current Quadrant Zoom value and
make Quadrant Zoom the active control.
[QZOOMC2U3] 0
[QZOOMC2U3] = STATUS/Current value
0 = Feedback of current value
[ + ] & [ - ] = Adjust as required
The zoom value will cycle through all five values
repeatedly when using the [ + ] and [ - ]
controls. For example, when the zoom value is
at 4 and the increment command is sent, the
next zoom value will be 0.
15. [BRIGnCi] - Set Value
This command sets the Brightness to an
absolute value and makes the Brightness
adjustment the active control.
Command Format: [BRIGnCiUy]
n= a value from 1 to 4
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 4 of unit ID 2.
Set the Brightness to the value of 2 by sending
the command [BRIG2C4U2].
16. [BRIGCi] - Status/Adjust
This command selects the Brightness
adjustment and makes it the active control. It
also returns the status of the current Brightness
level. As the active control, it may be adjusted
using the [ + ] and [ - ] commands.
Command Format: [BRIGCiUy]
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 2 of unit ID 3.
View the current Brightness and make
Brightness the active control.
[BRIGC2U3] 2
[BRIGC2U3] = STATUS/Current value
2 = Feedback of current value
[ + ] & [ - ] = Adjust as required
17. [SHARPnCi] - Set Value
This command sets the Sharpness to an
absolute value. It also makes the Sharpness
adjustment the active control.
Command Format: [SHARPnCiUy]
n= a value from 1 to 8
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
There is an MT106-100 in slot 4 of unit ID 2.
Set the Sharpness to the value of 2 by sending
the command [SHARP2C4U2].
18. [SHARPCi] - Status/Adjust
This command selects the Sharpness
adjustment and makes it the active control. It is
also used to return the status of the current
Sharpness level. As the active control, it may
be adjusted using the [ + ] and [ - ] commands.
Command Format: [SHARPCiUy]
Ci = card ID (i = slot number)
Uy = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)