Altinex UT250-101 manual Help, 17. ?, STA1, STA0, Designer Solutions

Models: UT250-101

1 22
Download 22 pages 45.92 Kb
Page 18
Image 18
16.[HELP]

DESIGNER SOLUTIONS

Example:

Send the command [AUTO2] to the UT250-101. If a video input signal is connected to any of the inputs, that signal will be connected to Outputs 2A and 2B only. A valid video signal on Input 1 takes precedence over Input 2, Input 2 over Input 3, and so on.

16.[HELP]

This command displays information available for the UT250-101interface commands.

Command Format: [HELP]

Example:

In order to display the RS-232 commands available for the UT250-101, send the command [HELP]. The commands along with a brief description will be displayed.

17.[?]

This command displays general information about a unit and its status.

Command Format: [?]

Example:

Send the command [?] to receive feedback status similar to the following.

[(UT250-101U0)(VR690-0268-001U0) (MA1111U0) (ON1111U0)]

The feedback is broken down as follows:

(UT250-101U0)

(VR690-0268-001U0)

(MA1111U0)

(ON1111U0)

All status feedback is enclosed in brackets, “[ ]“. Each data field within the status is enclosed in parentheses. The first two characters identify the status type. The last two characters are the unit’s ID.

UT250-101

= Model number

VR690-0268-001

= Firmware version

MA1111

= Matrix connections

ON1111

= Output ON/OFF status

The I/O connections are read left to right representing the four outputs (1A, 1B, 2A, 2B) and the input to which each is connected. The first digit shows the input number to which Output 1A is connected. The second digit is for Output 1B, and so on.

The ON/OFF status line is also read from left to right as Outputs 1A, 1B, 2A, and 2B. A "1" indicates the output is on and a "0" indicates the output is off.

18.[STA1]

This command enables automatic feedback. The command affects all units with auto-feedback capability, not just the UT250-101. The default is STA0, off.

Command Format: [STA1]

Example 1:

Command = [OFF] Feedback = (ON0000U0)

ON = Output ON/OFF status 0000 = Out 1-4 = OFF

U0 = Unit ID is U0

Example 2:

Command = [ON1A]

Feedback = (ON1000U0)

ON = Output ON/OFF status

1000 = Out 1=ON, 2-4=OFF

U0 = Unit ID is U0

19.[STA0]

This command disables automatic feedback. The command affects all units with auto-feedback capability, not just the UT250-101. The default is STA0, OFF.

Command Format: [STA0]

400-0503-001

17

Page 18
Image 18
Altinex UT250-101 manual Help, 17. ?, STA1, STA0, Designer Solutions