TROUBL E SHOO TING

SERV IC E

 

TROUBL E SHOO TING

 

• ELECTRONIC

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

 

 

 

 

Possible Cause

 

 

 

 

 

Code

 

Description/Results

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-10

 

Air Sensor Fault (shorted)

 

Air sensor is shorted.

 

 

 

 

 

 

 

 

 

Inoperative Oven

 

Air sensor is defective.

 

 

 

 

 

 

 

 

 

Air sensor is open or has connection failure.

 

 

E-11

Air Sensor Fault (open)

 

 

 

 

 

 

 

Inoperative Oven

 

Need air sensor test. See below.

 

 

E-30

 

Oven will not reach set temperature

 

Oven door closed? Door gasket need replacement? Preheat skipped?

 

 

 

 

Oven overloaded or has frozen product? Defective air sensor or probe?

 

 

 

Under temperatur

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective solid state relay? Bad wire connections or open heating cable?

 

 

 

 

 

 

 

 

Is the high limit switch tripped? If none of the above, call service.

 

 

E-31

 

Over temperatur

 

 

Shorted cable? Defective solid state relay? Defective air sensor?

 

 

 

 

 

Oven will shut down

 

If none of the above, call service.

 

 

E-60

 

Real time clock error

 

Appliance has probably been unplugged for more than 30 days. If this is the

 

 

 

 

 

 

Inoperative Oven

 

case, it should be plugged in with the circuit breaker ON, and the appliance

 

 

 

 

 

 

 

 

displaying the E-60 on the front panel for more than 30 minutes. Once this

 

 

 

 

 

 

 

 

has been accomplished, the circuit breaker should be turned OFF, or the

 

 

 

 

 

 

 

 

appliance unplugged for approximately 10 seconds after which the appliance

 

 

 

 

 

 

 

 

should be turned ON again.

 

 

 

 

 

E-70

 

 

Inoperative Oven

 

Check control connections for loose wires. If none, control must be replaced.

 

 

 

Configuration connector error

 

 

 

 

 

 

 

 

 

E-78

 

Voltage low

Inoperative Oven

 

If 125 VAC unit, voltage is below 90 VAC. Correct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If 208-240 VAC voltage is below 190 VAC. Correct.

 

 

E-79

 

Voltage high

Inoperative Oven

 

If 125 VAC unit, voltage is over 130 VAC. Correct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If 208-240 VAC, voltage is over 250 VAC. Correct.

 

 

E-80

 

 

Inoperative Oven

 

Replace control.

 

 

 

 

 

 

EEPROM - Function data error

 

 

 

 

 

 

 

 

 

E-82

 

 

Inoperative Oven

 

Replace control.

 

 

 

 

 

 

EEPROM - Calibration data error

 

 

 

 

 

 

 

 

 

E-84

 

 

Inoperative Oven

 

Replace control.

 

 

 

 

 

 

EEPROM - Unit ID error

 

 

 

 

 

 

 

 

 

E-86

 

 

Inoperative Oven

 

Replace control.

 

 

 

 

 

 

EEPROM - Preset data error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To test air sensor:

 

 

 

 

 

 

 

 

 

 

 

Test air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale.

 

 

 

 

The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs

 

 

 

 

to be replaced.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

DA NG ER

 

 

THIS SECTION IS PROVIDED FORTHE ASSISTANCE

 

 

 

DISCO NNECT UNI T FROM

 

 

OF QUALIFIED SERVICETECHNICIANS ONLYAND

 

 

 

POWER SOUR CE BEFORE

 

 

IS NOT INTENDED FOR USE BY UNTRAINED OR

 

 

 

 

 

 

 

 

CLEANING OR SERV ICING .

 

 

UNAUTHORIZED SERVICE PERSONNEL.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation /S ervice

Manual • 16.

 

 

 

 

 

 

Dr awe r

War mer Ins tallation/

 

Page 17
Image 17
Alto-Shaam 1DN Da Ng Er, Troubl E Shoo Ting, Electronic, Control, To test air sensor, Disco Nnect Uni T From, Error, Code