SE RVICE
| TROU BLES HOOTI NG GU ID E - ELECTRONIC | CONT ROL |
| ||
|
|
|
|
|
|
| Error |
| Possib le Cause |
|
|
| Code | Descr ipti on/Result s | Service Required |
|
|
|
|
|
|
| |
| Air Sensor Fault (sho rted) | Air senso r is shorte d. Air sens or defect ive? |
| ||
|
| Inoperative Oven | Detach the sensor from the term ina l block. Use an Ohm meter to measure |
| |
|
|
| the resi stance of the sensor . Chec k sensor at 32°F (0°C) using a contai ner of |
| |
|
|
| ice water. If Ohm readi ng is 100, repla ce displ ay. If Ohm reading is not 100, |
| |
|
|
| repl ace sensor . |
|
|
| Air Sensor Fault (open) | Air senso r is open or connec tion fail ure. Air sensor defec tive ? |
| ||
|
| Inoperative Oven | Detach the sensor from the term ina l block. Use an Ohm meter to measure |
| |
|
|
| the resi stance of the sensor . Chec k sensor at 32°F (0°C) using a contai ner of |
| |
|
|
| ice water. If Ohm readi ng is 100, repla ce displ ay. If Ohm reading is not 100, |
| |
|
|
| repl ace sensor . |
|
|
| Under tem per atu re | Oven door closed? Door gasket need replacement? Preheat skipped? |
| ||
|
| Oven will not reach set temperature | Oven overloa ded or has frozen product? Defective air sensor or probe? |
| |
|
| Defective soli d state relay? Bad wire connections or open heating cable? |
| ||
|
|
| Is the high limit switch tripped? If none of the above, call service. |
| |
| Over temper ature | Shor ted cable? Defe ctive sol id stat e relay? Defe ctive air sensor? |
| ||
|
| Ove n will shut down | If non e of the above, call servic e. |
|
|
| EEPROM - Funct ion data error | Cont act Service . |
|
| |
|
| Inoperative Oven | Cont act Service . |
|
|
| EEP ROM - Calibration data error |
|
| ||
|
| Inoperative Oven |
|
|
|
TROU BLES HOOTI NG GU ID E - MANUAL CONTROL
TROU BLE | POSSIBLE CAUSE | REMEDY |
|
|
|
Unit does not operat e | Insuffi cient powe r supply | Check power source. |
| Defecti ve power cord or plu g | Check and replace if necessary |
| Defecti ve power switch. | Check and replace if necessary . |
| Defecti ve thermostat. | Replace thermostat and calibrate. |
|
|
|
Cannot control temp eratu re. | Defecti ve thermo sta t. | Replace thermostat and calibrate. |
| Grounded element. | Replace element (Check ele ment to |
|
| ground Ohm Elem ent @ 27.7 Ohms) |
|
|
|
Tempera ture gauge read out incorrect. | Defecti ve temperature gauge | Replace temperature gauge. |
| Calibration off. | Calibrate according to instructi ons |
|
| found on page 9. |
|
|
|
AR- 7H Hot Hol din g Rot is ser ie Co mpani on Operation & Care Manual • 15