Alto-Shaam AR-7H ELECTRONIC CONTROL Se Rvice, Trou Bles Hooti Ng Gu Id E - Electronic, Cont Rol

Models: AR-7H ELECTRONIC CONTROL AR-7H MANUAL CONTROL Hot Holding Rotisserie Companion

1 33
Download 33 pages 52.9 Kb
Page 16
Image 16
SE RVICE

SE RVICE

 

TROU BLES HOOTI NG GU ID E - ELECTRONIC

CONT ROL

 

 

 

 

 

 

 

 

Error

 

Possib le Cause

 

 

 

Code
Descr ipti on/Result s
Service Required

 

 

 

 

 

 

 

 

E-10Air Sensor Fault (sho rted)

Air senso r is shorte d. Air sens or defect ive?

 

 

 

Inoperative Oven

Detach the sensor from the term ina l block. Use an Ohm meter to measure

 

 

 

 

the resi stance of the sensor . Chec k sensor at 32°F (0°C) using a contai ner of

 

 

 

 

ice water. If Ohm readi ng is 100, repla ce displ ay. If Ohm reading is not 100,

 

 

 

 

repl ace sensor .

 

 

 

E-11Air Sensor Fault (open)

Air senso r is open or connec tion fail ure. Air sensor defec tive ?

 

 

 

Inoperative Oven

Detach the sensor from the term ina l block. Use an Ohm meter to measure

 

 

 

 

the resi stance of the sensor . Chec k sensor at 32°F (0°C) using a contai ner of

 

 

 

 

ice water. If Ohm readi ng is 100, repla ce displ ay. If Ohm reading is not 100,

 

 

 

 

repl ace sensor .

 

 

 

E-30Under tem per atu re

Oven door closed? Door gasket need replacement? Preheat skipped?

 

 

 

Oven will not reach set temperature

Oven overloa ded or has frozen product? Defective air sensor or probe?

 

 

 

Defective soli d state relay? Bad wire connections or open heating cable?

 

 

 

 

Is the high limit switch tripped? If none of the above, call service.

 

 

E-31Over temper ature

Shor ted cable? Defe ctive sol id stat e relay? Defe ctive air sensor?

 

 

 

Ove n will shut down

If non e of the above, call servic e.

 

 

 

E-80EEPROM - Funct ion data error

Cont act Service .

 

 

 

 

Inoperative Oven

Cont act Service .

 

 

 

E-82EEP ROM - Calibration data error

 

 

 

 

Inoperative Oven

 

 

 

TROU BLES HOOTI NG GU ID E - MANUAL CONTROL

TROU BLE

POSSIBLE CAUSE

REMEDY

 

 

 

Unit does not operat e

Insuffi cient powe r supply

Check power source.

 

Defecti ve power cord or plu g

Check and replace if necessary

 

Defecti ve power switch.

Check and replace if necessary .

 

Defecti ve thermostat.

Replace thermostat and calibrate.

 

 

 

Cannot control temp eratu re.

Defecti ve thermo sta t.

Replace thermostat and calibrate.

 

Grounded element.

Replace element (Check ele ment to

 

 

ground Ohm Elem ent @ 27.7 Ohms)

 

 

 

Tempera ture gauge read out incorrect.

Defecti ve temperature gauge

Replace temperature gauge.

 

Calibration off.

Calibrate according to instructi ons

 

 

found on page 9.

 

 

 

AR- 7H Hot Hol din g Rot is ser ie Co mpani on Operation & Care Manual • 15

Page 16
Image 16
Alto-Shaam AR-7H ELECTRONIC CONTROL Se Rvice, Trou Bles Hooti Ng Gu Id E - Electronic, Cont Rol, Possible Cause, Remedy