Installing 4-Wire Power Cord

WARNING

To avoid the risk of severe electrical shock or death, ground wire must be attached to frame of range, using ground screw provided. Ground wire must not contact any other terminal.

 

Neutral Terminal

Power lead

connect wire with white

connect wire with black or

insulation

red insulation and brass

 

terminal

 

Power Terminals

Power Line

connect wire with black or

(240 or 208 volts

red insulation and brass

both sides)

terminal

 

Converting 3-Wire to 4-Wire Power Cord

1.Remove rear wire cover.

2.Remove bottom strain relief screw and retain for further use.

3.Remove screw/hex nuts from terminal block and retain for further use.

4.Remove all 3-wire or cable leads from the terminal block and proceed to remove the power cord from the unit by pulling in a downward motion so that cord is removed from strain relief.

5.Remove the grounding strap attached to the center terminal on the terminal block.

Grounding strap is not needed for this installation.

Remove green ground screw and retain for future use.

6.To install the 4-wire cord, please follow step 3 through step 9 of Installing 4-Wire Power Cord section.

7.Reinstall rear cover and secure it with screw removed earlier.

Level Range

CAUTION

To avoid damaging oven door, do not lift or move range by oven door handle. Glass can break.

Figure 6

1. Remove rear wire cover.

2. Place strain relief (winged clamp) in cord access hole below terminal block.

• Place wings through hole entering from bottom.

• Screw holes in clamp should be below mounting panel.

3. Remove grounding strap attached to center terminal on terminal block.

• Strap is not needed for this installation.

• Remove green ground screw and retain for use in step 7.

4. Place cord through strain relief.

• Attach cord neutral (center) or white wire to center terminal on terminal block.

5. Attach power lead, red wire or black wire to left terminal. (Figure 6)

6. Attach power lead, red wire or black wire to right terminal.

7. Attach green or bare wire to back of range using green ground screw previously removed in step 3.

8. Attach wires using hex nuts provided.

• Firmly tighten to ensure proper electrical connection.

9. Place screw through strain relief, tighten, and replace

rear wire cover.

8

Carefully level range using legs provided. Range must be level to cook and bake uniformly.

Place a level on top oven rack or on range top when leveling.

Leveling legs must extended ¼ inch to engage anti-tip bracket.

Removal and Replacement of Range

1.Disconnect power to range.

2.Slide range forward.

3.Unplug range cord and place range aside.

4.Remove anti-tip bracket.

5.Install anti-tip bracket into new location using instructions provided with bracket or see Anti-tip Bracket Installation section in this manual.

6.To reinstall range, follow instructions in Installation section of this manual.

Page 8
Image 8
Amana ARR6400, ART6610, ART6710, ART6510 Installing 4-Wire Power Cord, Converting 3-Wire to 4-Wire Power Cord, Level Range