Amcor ALD-1 2, ALD-12 Drainage, Specifications, By the Draining into a Container, Remarks

Models: ALD-1 2 ALD-12

1 8
Download 8 pages 46.24 Kb
Page 3
Image 3
Drainage

Drainage

During the process of cooling, some water will be extracted from the air into the unit. Most of this water is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air Conditioners. If the unit is operated in VERY HUMID air, water will collect in the container inside the unit. If the water container is full, the compressor will stop, but the fan will continue to circulate the air. The POWER indicator will blink to inform you to empty the internal container. To make the cooling function work again, please empty the water by one of the following methods:

By the Draining into a Container

Use a Shallow Container or Dish

1.Turn off the unit.

2.Position a flat container or dish under the drain hole.

Do not allow the water to drip continuously into the container, as it might easily overflow.

3.Remove the drain knob & rubber plug from the drain hole. The condensed water will drain out automatically.

4.When the container is almost full, replace the rubber plug into the drain hole to stop the water. Empty the container.

5.Repeat steps 2, 3 & 4 until all the condensed water is emptied.

6.Once all the condensed water has been removed, replace the rubber plug into the drain hole firmly. The Full Water indicator should be off now.

7.Replace the drain knob.

By Water Tube (Continuous Drainage)

1.Remove the drain knob and rubber plug and keep them for future use.

2.Connect a suitable water tube

(of 3/4" internal diameter - supplied) to the water hole. The condensed water will drain out automatically.

3.If you want to extend the water tube you can connect it with another tube (outside diameter 3/4").

Special Caution for Heating Function!

While using the heating function, please note:

1.Install the exhaust pipe securely in order to exhaust the cool air to the outside (please see page 6).

2.Use the continuous drainage option as described above.

3.The warmer the outside air the more heat will be

pumped into the room. Working range for heat pump function is 41°F to 81°F. When used in room temperatures outside this range, the unit may not function properly.

4.While using the heating function during low temperatures, sometimes the heating will stop for a while in order to melt the internal frost. When this occurs, just wait for heating to resume. This is normal for compressor operated devices.

Specifications

Model Number

ALD-12,000E

ALD-12,000EH

 

 

 

Cooling Capacity

12,000 BTU/hr

12,000 BTU/hr

 

 

 

Heating Capacity (1)(2)

N/A

12,000 BTU/hr

 

 

 

Power Consumption

950W / 9A

950W / 9A

 

 

 

Humidity Removal Capacity

55 Pts. / Day

55 Pts. / Day

 

 

 

Recommended room size*

400 sq. ft.

400 sq. ft.

 

 

 

Power Supply

120V / 60Hz / 1 Phase

120V / 60Hz / 1 Phase

 

 

 

Compressor

Rotary

Rotary

 

 

 

Refrigerant

R-22

R-22

 

 

 

Fan Speed

2

2

 

 

 

Timer

1-12 hours

1-12 hours

 

 

 

Thermostat

64°F - 90°F

64°F - 90°F

 

 

 

Net Weight

65 lbs.

68 lbs.

 

 

 

Dimensions

16"W x 17"D x 30"H

16"W x 17"D x 30"H

 

 

 

Working Temperature

Cooling: 64°F to 110°F

Cooling: 64°F to 110°F

 

 

Heating: 41°F to 81°F

 

 

 

REMARKS:

1. The data may vary, please refer to the rating label on the back of the unit.

2. The above conditions are measured at: Cooling - Indoor: RT 81°F, RH 60% Heating - Indoor: RT 68°F, RH 60%

* Uninsulated rooms such as sunrooms, garages, or attics should be less than 400 sq. ft.