TROUBLE SHOOTING

GB

TROUBLE SHOOTING

Never try to repair or dismantle the unit yourself. Before calling for assistance please check the points below.

The unit doesn’t run.

Is the machine plugged in?

 

Is the mains power supply on?

 

Is the water tank full indicator on? (If so, the water tank is full or it isn’t

 

positioned properly).

The unit seems to

Are too many windows or doors open?

extract little water.

Is there something in the room producing lots of heat?

 

Is the room cold – the colder the air the less moisture the unit will extract.

 

Is the filter dirty?

 

Is the room humidity already quite low?

The unit seems to do

Is the filter dirty?

nothing.

Is the air intake or outlet blocked?

 

Is the room humidity already quite low?

 

Is the room temperature below 5 °C? The fan may run without the compressor.

Too noisy.

Is the machine positioned unevenly so as to create vibration?

 

Is the floor underneath the unit uneven or loose fitting?

 

Is there any foreign body interfering with the unit?

The unit’s fan doesn’t

Is the filter blocked?

seem to be revolving.

Is there any foreign body interfering with the unit?

The continuous

Does the hose have a downward slope throughout its entire length?

drainage is not working.

Is there a kink or sharp bend in the hose?

TECHNICAL DATA

Model

 

QT 120

Power supply

 

220 - 240 V / 50 Hz

Power consumption (at 27 °C, 90% RH)

W

195

Moisture removal (at 32 °C, 90% RH)

L/24h

12

Refrigerant

 

R-134A

Refrigerant load

g

180

Working temperature

°C

5 - 35

Dimensions (W x D x H)

cm

33,7 x 28,6 x 53,5

Nett weight

kg

13

Due to our continuous R+D program, specifications may change without prior notice.

For current specifications please refer to the rating label on your machine.