American Dryer Corp M31 manual GAS VALVE/IGNITION System Removal

Models: M31

1 12
Download 12 pages 30.06 Kb
Page 5
Image 5

For Models M31,M50,M75

To remove motorized impellor assembly:

Remove the six hex nuts shown with arrows. Now pull the blower motor assembly apart from the blower housing. Remove the four phillips screws shown with arrows and separate the motorized impellor from the blower motor mount.

To remove motorized impellor assembly, remove lint housing cover, lint screen, and the four screws shown with arrows. Pull the motorized impellor assembly out through the opening.

GAS VALVE/IGNITION SYSTEM REMOVAL:

Be sure to shut off the gas main and then proceed to remove electrical connections and screws indicated. Remove lower front panel. Disconnect union and screws noted with arrows.

By removing the top screws you will be able to remove the burner tube. After, removing the top burner, without damaging the Hot Surface Ignitor, remove the whole gas valve assembly. Be careful during assembly not to damage the Hot Surface Ignitor. Replace assembly in the reverse order.

Inspect all wires to be sure all lead directly toward the front of the dryer. Be sure no wires are caught on the burner tube or ignitor.

For Models M31,M50,M75

Gas Valve Ingnition System

450280-1

www.amdry.com

5

Page 5
Image 5
American Dryer Corp M31 manual GAS VALVE/IGNITION System Removal