continued from page 48
c.Ignitor does not spark and Direct Spark Ignition (DSI) module
1)Fault in high voltage (HV) wire...
a)Break in wire.
b)Loose connection.
c)Failed ignitor probe assembly.
d)Failed Direct Spark Ignition (DSI) module.
STEAM MODELS
1.No (external) compressed air (80 PSI [552 kPa] required) to steam damper solenoid.
2.Flow control valve is not adjusted correctly ...
a.Too much restriction.
3.Failed steam damper pneumatic (air) solenoid.
4.Damper stuck in "closed" position...
a.Check for obstruction.
5.Leak in the pneumatic (air) system.
6.Failed air piston.
W. Dryer operates but is taking too long to dry...
1.Exhaust duct work run too long or is undersized...back pressure cannot exceed 0.3 inches water column (0.74 millibars).
2.Restriction in exhaust ...
a.
b.Restriction in duct work ...
1)Check duct work from dryer ALL the way to the outdoors.
3.Insufficient
4.Impellor (blower/fan) "squirrel cage" is rotating in the wrong direction.
5.Lint drawer screen is dirty or is not being cleaned often enough.
continued on page 50
49