2.Technical Gas Data a. Gas Specifications

 

 

TYPE OF GAS

 

 

 

 

 

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

Inline Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

*Measured at outlet side of gas valve pressure tap when gas valve is on.

b.Gas Connections:

Inlet connection ---- 1-inch N.P.T.

Inlet supply size ----- 1-inch N.P.T. (minimum)

Btu/hr input (per dryer) ----- 550,000 (138,600 kcal/hr)

1)Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must be consistent between a minimum of 6-inches (14.92 millibars) and a maximum of 12-inches water column (29.9 millibars) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5-inches water column (26.1 millibars). There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

 

 

 

TYPE OF GAS

 

L.P.

 

 

 

 

 

 

 

 

 

 

Conversion

ADC

BTU

 

 

Natural

 

 

Liquid Propane

kcal/hr

 

 

 

Kit

MODEL

Per Hour

 

 

 

 

 

 

 

Rating

Qty.

D.M.S.*

 

Part

Qty.

D.M.S.*

Part

Part Number

NUMBER

Rating

 

Number

Number

 

 

 

 

 

 

 

MDG-170

550,000

138,600

4

#2

 

140839

4

#29

140820

880978

 

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

* D.M.S. (Drill Material Size) equivalents are as follows:

Natural Gas

#2

= .2210" (5.6134 mm)

Liquid Propane Gas ..

#29

= .1360" (3.4544 mm)

26