I. PREPARATION FOR OPERATION/START-UP
The following items should be checked before attempting to operate the dryer;
1.Read ALL "CAUTION," "WARNING," and "DIRECTION" labels attached to the dryer.
2.Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to the left inside front side panel (refer to the illustration in Section IX of this manual). In case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service exactly.
3.GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the dryer data label.
4.GAS MODELS - the sail switch damper assembly was installed and adjusted at the factory prior to shipping. However, each sail switch adjustment must be checked to assure that this important safety control is functioning.
5.Check to be sure drive belts between idler pulley and motor pulley have been reconnected.
NOTE: The drive belts were disconnected at factory prior to shipment.
6.GAS MODELS - be sure that ALL gas
7.Be sure ALL back panels (guards) and electric box covers have been replaced.
8.Check ALL service doors to assure that they are closed and secured in place.
9.Be sure lint drawer is securely in place.
NOTE: LINT DRAWER MUST BE ALLTHE WAY IN PLACE TO ACTIVATE SAFETY
SWITCH OTHERWISE THE DRYER WILL NOT START.
10.Rotate the basket (tumbler) by hand to be sure it moves freely.
11.Check bolts, nuts, screws, terminals, and fittings for security.
12.GAS MODELS and STEAM MODELS - check to insure air supply to the dryer (80 PSI [552 kPa]) is on.
13.STEAM MODELS - check to insure ALL steam
14.STEAM MODELS - check steam damper operation.
15.Check tumbler bearing set screws to insure they are ALL tight.
33