American Dryer Corp ML-75DII SPECIFICATIONS/COMPONENT Identification, Specifications

Models: ML-75DII

1 58
Download 58 pages 42.83 Kb
Page 10
Image 10

SECTION II

SPECIFICATIONS/COMPONENT IDENTIFICATION

A. SPECIFICATIONS

BASKET (TUMBLER) DIAMETER

37”

 

94 cm

 

 

 

 

 

BASKET (TUMBLER) DEPTH

36”

 

91.5 cm

 

 

 

 

 

BASKET (TUMBLER) MOTOR

1 HP*

 

0.746 kw

 

 

 

 

 

DOOR OPENING (DIAMETER)

31-3/8”

 

79.7 cm

 

 

 

 

 

BASKET (TUMBLER) VOLUME

22.4 cu. ft.

 

0.634 cu. m.

 

 

 

 

 

DRYERS PER 20’/40’ CONTAINER

10/20

 

 

 

 

 

 

DRYERS PER 45’/48’ TRUCK

24/24

 

 

 

 

 

 

 

VOLTAGE AVAILABLE

120-460v 1ø-3ø 50/60 Hz

 

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

721 lbs.

 

327 kg

Gas

 

 

 

 

 

 

APPROX. WEIGHT (CRATED)

771 lbs.

 

349.7 kg

 

 

 

 

 

 

 

 

 

 

HEAT INPUT

 

200,000 btu/hr

 

50,400 kcal/hr

 

 

 

 

 

 

 

 

AIRFLOW

 

1,200 cfm

 

33.98 cmm

 

 

 

 

 

 

 

INLET PIPE SIZE

 

3/4” N.P.T.**

 

 

 

 

 

 

 

Electric

VOLTAGE AVAILABLE

208-460v 1ø-3ø

50/60 Hz

 

 

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

721 lbs.

 

327 kg

 

 

 

 

 

 

 

APPROX. WEIGHT (CRATED)

771 lbs.

 

349.7 kg

 

 

 

 

 

 

 

 

AIRFLOW

 

1,200 cfm

 

33.98 cmm

 

 

 

 

 

 

VOLTAGE AVAILABLE

120-460v 1ø-3ø 50/60 Hz

 

 

 

 

 

 

 

APPROX. WEIGHT (UNCRATED)

757 lbs.

 

343.4 kg

 

 

 

 

 

 

 

APPROX. WEIGHT (CRATED)

807 lbs.

 

366.1 kg

 

 

 

 

 

 

 

Steam

AIRFLOW

 

1,350 cfm

 

38.23 cmm

 

 

 

 

 

 

COMPRESSED AIR VOLUME

BOILER HP NORMAL

 

0.02 cmh

 

0.75 cfh

 

 

AIR CONNECTION

1/8” F.P.T.

 

STEAM CONSUMPTION

LOAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

238.7 lbs./hr

 

108.3 kg/hr

7

 

 

 

 

 

 

 

 

 

OPERATING STEAM PRESSURE

STEAM SUPPLY

STEAM RETURN

 

 

 

 

 

 

 

 

125 PSI max

 

8.6 bars

1” F.P.T.

1” F.P.T.

 

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

*For non-reversing models.

**A minimum of 3/4-inch pipe must be supplied to the gas inlet for each dryer.

IMPORTANT: Steam dryers must be provided with clean, dry, and regulated 80 PSI +/- 10 PSI (5.51 bars +/- 0.69 bars) air supply.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6

Page 10
Image 10
American Dryer Corp ML-75DII installation manual SPECIFICATIONS/COMPONENT Identification, Specifications