SECTION VIII

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is located in the upper rear area of the dryer.

Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Adjustment Position Number

 

1

2

3

4

5

 

 

 

 

 

 

 

Time in Seconds*

 

30

60

90

120

150

 

 

 

 

 

 

 

DWELL (Stop) TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment Position Number

 

1

2

3

4

5

 

 

 

 

 

 

 

Time in Seconds*

 

5

6.3

7.6

8.9

10.2

 

 

 

 

 

 

 

* Values shown are +/- 1 second.

 

 

 

 

 

49

Page 53
Image 53
American Dryer Corp ML-75DII installation manual Timing Legend, Reversing Timer SPIN/DWELL Adjustments