2.Electrical Service Specifications a. Gas and Steam Models Only
MLS-75 (STEAM )
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual element, time delay, current limiting, class RK1 or RK5 ONLY.
B.Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for
SERVICE | PHASE | WIRE | APPROX. | MINIMUM | FUSING | CIRCUIT | ||
Dual Element | ||||||||
VOLTAGE | SERVICE | AMP DRAW | WIRE SIZE | BREAKER | ||||
|
|
|
|
|
| Time Delay |
| |
120 | (60 Hz) | 1ø | 2 | 13 | * | 20 | 25 | |
|
|
|
|
|
|
|
| |
208 | (60 Hz) | 1ø | 2 | 7.6 | * | 12 | 15 | |
|
|
|
|
|
|
|
| |
208 | (60 Hz) | 3ø | 3/4 | 4.7 | * | 8 | 15 | |
|
|
|
|
|
|
|
| |
240 | (50/60 Hz) | 1ø | 2 | 7 | * | 12 | 15 | |
|
|
|
|
|
|
|
| |
240 | (50/60 Hz) | 3ø | 3/4 | 4.9 | * | 8 | 15 | |
|
|
|
|
|
|
|
| |
(50 Hz) | 3ø | 3/4 | 3 | * | 5 | 15 | ||
|
|
|
|
|
|
|
| |
416 | (50 Hz) | 3ø | 3/4 | 3.1 | * | 5 | 15 | |
|
|
|
|
|
|
|
| |
460 | (60 Hz) | 3ø | 3/4 | 2.8 | * | 5 | 15 | |
|
|
|
|
|
|
|
|
*AWG Stranded Wire Type ... size wire as per National Electrical Code or local codes.
IMPORTANT: Figures shown are for
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
20