American Dryer Corp ML-75DII installation manual MLS-75 Steam

Models: ML-75DII

1 58
Download 58 pages 42.83 Kb
Page 24
Image 24

2.Electrical Service Specifications a. Gas and Steam Models Only

MLG-75 (GAS)

MLS-75 (STEAM )

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. Fuse ratings are dual element, time delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

Dual Element

VOLTAGE

SERVICE

AMP DRAW

WIRE SIZE

BREAKER

 

 

 

 

 

 

Time Delay

 

120

(60 Hz)

1ø

2

13

*

20

25

 

 

 

 

 

 

 

 

208

(60 Hz)

1ø

2

7.6

*

12

15

 

 

 

 

 

 

 

 

208

(60 Hz)

3ø

3/4

4.7

*

8

15

 

 

 

 

 

 

 

 

240

(50/60 Hz)

2

7

*

12

15

 

 

 

 

 

 

 

 

240

(50/60 Hz)

3/4

4.9

*

8

15

 

 

 

 

 

 

 

 

380-400

(50 Hz)

3ø

3/4

3

*

5

15

 

 

 

 

 

 

 

 

416

(50 Hz)

3ø

3/4

3.1

*

5

15

 

 

 

 

 

 

 

 

460

(60 Hz)

3ø

3/4

2.8

*

5

15

 

 

 

 

 

 

 

 

*AWG Stranded Wire Type ... size wire as per National Electrical Code or local codes.

IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the factory.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

20

Page 24
Image 24
American Dryer Corp ML-75DII installation manual MLS-75 Steam