SECTIONVIII

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECTAND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOWACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OFANY EQUIPMENT PER OSHA (Occupational Safety and HealthAdministration)

STANDARDS.

The information provided will help isolate the most probable component(s) associated with the difficulty described. The experienced technician realizes, however, that a loose connection or broken/shorted wire may be at fault where electrical components are concerned ... and not necessarily the suspected component itself.

Electrical parts should always be checked for failure before being returned to the factory.

The information provided should not be misconstrued as a handbook for use by an untrained person making repairs.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the fuse being replaced.

WARNING: ALL SERVICE AND TROUBLESHOOTING SHOULD BE PERFORMED BYA QUALIFIED PROFESSIONAL OR SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALLSAFETY PRECAUTIONS DISPLAYED ON THE DRYER OR SPECIFIED IN THIS MANUAL.

A.No light emitting diode (L.E.D.) display...

1.Service panel fuse blown or tripped breaker.

2.Blown control circuit fuse (3AG 1/2-Amp [Slo Blo] Fuse).

3.Failed Dual Microprocessor Controller (DMC) computer.

B.Basket (tumbler) does not start, but motor and DMC computer motor L.E.D. dot and motor output L.E.D. indicators are on...

1.DMC computer indicator is on...

a.Failed motor contactor/relay.

b.Failed motor.