American Dryer Corp MLG31PCA installation manual

Models: MLG31PCA

1 51
Download 51 pages 59.47 Kb
Page 31
Image 31

3)Start the dryer by pressing the desired setting for either the upper basket (tumbler) or lower basket (tumbler) (i.e., “LO” selection for the upper basket/tumbler). The light emitting diode (L.E.D.) display will now read selection (setting) made and the amount of time vended (i.e., “LO 10”).

NOTE: The dryer can be stopped at any time by opening the main door. To restart the dryer, shut the main door and press desired setting.

4)Open main door to stop the dryer, and change selection to “PERM PRESS” (medium) setting. Repeat this procedure, but change the selection (setting) to “HI” (high). This will confirm that the setting key circuits and door switch circuits are functioning properly.

NOTE: Selection (setting) changes can be made at any time during the drying cycle by opening and closing the main door and then making a new selection.

5)Repeat above procedure for the other basket (tumbler).

b.OPL (Non-Coin) Models Only

1)The L.E.D. display(s) will flash back and forth between “FILL” and “FrEE” meaning that the dryer is available.

2)Start the dryer by pressing the desired setting for either the upper basket/tumbler or lower dryer basket/tumbler (i.e., “LO” selection for the upper basket/tumbler). The L.E.D. display will now read selection (setting) made and the drying time portion of the L.E.D. display will read “00” and count upwards in time.

NOTE: The dryer can be stopped at any time by opening the main door. To restart the dryer, shut the main door and press the desired setting.

3)Open main door to stop the dryer and change selection to “PERM PRESS” (medium) setting. Repeat this procedure, but change the selection (setting) to “HI” (high). This will confirm that the setting key circuits and door switch circuits are functioning properly.

NOTE: Selection (setting) changes can be made at any time during the drying cycle by opening and closing the main door and then making a new selection.

4)Repeat above procedure for the other basket (tumbler).

3.Heat Circuit Operational Test

a.Gas Models

When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.

The dryer is equipped with a Direct Spark Ignition (DSI) system which has internal diagnostics. If ignition is not established after three (3) attempts, the heat circuit DSI module will lockout until it is manually reset. To reset the DSI system, open and close the main door and restart the dryer (press desired temperature selection).

27

Page 31
Image 31
American Dryer Corp MLG31PCA installation manual