American Megatrends MAN-758 Connect SCSI I/O, Continued, MegaRUM PCI Motherboard User’s Guide

Models: MAN-758

1 89
Download 89 pages 41.29 Kb
Page 42
Image 42
(1.5 meter-(SCSI signal length on AMI RAID)-(SCSI length in storage box)

Step 11 Connect SCSI I/O, Continued

Single-Ended Ultra SCSI Understanding the cable requirements, termination and stub lengths is key to the successful implementation of a Ultra-SCSI subsystem.

SCSI Cables - Up to Four Devices The total external SCSI cable length for single-ended when using up to 4 Ultra-SCSI devices (maximum. capacitance of device = 25pf) should be less than or equal to:

(3 meter-(SCSI signal length on AMI RAID)-(SCSI length in storage box)

=(3 meter - 0.305 meter - SCSI length in storage box)

=2.695 - SCSI length in storage box

SCSI Cables - More than Four Devices The total external SCSI cable length for single-ended when using from five to eight Ultra-SCSI devices (max. cap of device = 25pf) should be less than or equal to:

(1.5 meter-(SCSI signal length on AMI RAID)-(SCSI length in storage box)

=(1.5 meter - 0.305 meter - SCSI length in storage box)

=1.195 - SCSI length in storage box

Spacing Devices The SCSI devices should be uniformly spaced between terminators with the end devices located as close as possible to the terminators.

SCSI Signal Path The SCSI signal path is a controlled impedance environment with the following characteristic impedance:

90 ohms +/- 6 ohms for the REQ and ACK signals

90 ohms +/- 10 ohms for all other signals

Cont’d

38MegaRUM PCI Motherboard User’s Guide

Page 42
Image 42
American Megatrends MAN-758 manual Connect SCSI I/O, Continued, MegaRUM PCI Motherboard User’s Guide